2-
4
13
)
Measure the width of effective sealing face. Replace the cylinder head or
valve if it is beyond the limit. Service limit:
>
1.6mm
14
)
Ream the valve seat to specified value. Replace it if it is beyond the limit.
Standard valve: intake
Φ
29
±
0.05mm
,
exhaust
Φ
25
±
0.05mm
15
)
Measure I.D. of valve guide. If it is out of the limit, replace the worn valve
guide. Service limit:
>
Φ
5.54mm
16
)
Unscrew the spark plug M10
×
1. Clear away carbon deposit around the
spark plug. The spark plug gap should be controlled between the scope of
0.8
~
0.9mm.
(NOTE: Tightening torque of spark plug M10
×
1:10
~
20N.m)