background image

 

4

PREPARATION

These installation instructions provide all the
information needed for positioning the Extended
Battery Cabinet (including environmental
requirements) and for connecting the input and
output power cables.

Inspection

Upon receiving the Extended Battery Cabinet,
examine the packaging for any signs of
mishandling or damage. If any damage is noted,
call your local Liebert representative and/or notify
your carrier.

Environment

Required Setup Equipment

The tools below are required in order to properly
set up your Extended Battery Cabinet.

• Pallet jack
• 13 mm or 1/2" wrench
• Flathead screwdriver
• #2 Phillips screwdriver

Site Preparation

When deciding where to locate your Extended
Battery Cabinet, consider the weight and size of
the unit. Make sure that the structural integrity of
the floor can withstand the weight. Refer to the
table below for size and fully populated weight
considerations:

Check to make sure that your Extended Battery
Cabinet will be located in a well-ventilated area
with at least 300 mm (12”) behind it. It should have
at least one meter (39 in.) in front to change
modules when necessary.

The unit frame is bolted to the shipping pallet to
ensure safety. It is recommended that a pallet jack
be used to transport the unit to its operating
location (prior to unbolting the unit).

NOTE

Operating in temperatures above 77°F 

(25°C) will reduce battery life. The 

environment must be free of conductive 

contaminants and excessive moisture 

(water condensation), flammable vapors, 

chemical fumes, or corrosive gases and 

liquids.

Max Weight

lbs (kg)

H x W x D

in (mm)

942

(427)

52" x 20" x 28"

(1320 x 508 x 711)

1 meter
(39 in.)

300 mm
(12 in)

Содержание Nfinity Extended Battery Cabinet

Страница 1: ...POWER PROTECTION Extended Battery Cabinet for Nfinity USER MANUAL...

Страница 2: ......

Страница 3: ...N 4 INSPECTION 4 ENVIRONMENT 4 REQUIRED SETUP EQUIPMENT 4 SITE PREPARATION 4 UNLOADING 5 UNLOADING THE EXTENDED BATTERY CABINET 5 STATIONARY MOUNTING 6 OPTIONAL STATIONARY MOUNTING 6 INSTALLATION 7 GR...

Страница 4: ......

Страница 5: ...er must correct at his own expense Operating Environment Operate the Extended Battery Cabinet in an indoor environment only in an ambient temperature range of 32 F to 104 F 0 C to 40 C For optimum bat...

Страница 6: ...tput Requests the user to consult the manual Indicates the unit contains a valve regulated lead acid battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage OFF ON Standby...

Страница 7: ...m of 12 battery modules with the same level of monitoring and control as the battery modules fitted in the UPS Features Up to four Extended Battery Cabinets can be used with a single Nfinity UPS Up to...

Страница 8: ...weight and size of the unit Make sure that the structural integrity of the floor can withstand the weight Refer to the table below for size and fully populated weight considerations Check to make sure...

Страница 9: ...allet and cabinet Keep brackets and bolts for future transportation of cabinet or for additional sta bility once in place 3 Remove the metal ramp from the bottom of the battery cabinet rotating it Fit...

Страница 10: ...Additional stability can be added by bolting the mounting brackets used in shipping to the floor Optional Stationary Mounting For greater stability use a higher grade bolt Refer to the dimensions belo...

Страница 11: ...en the two cards DC Power DC connection with the UPS unit must be via the factory supplied battery cables or if longer connection cable is required via the optional Extended Battery Cable kits See bel...

Страница 12: ...f Extended Battery Cabi nets installed Press return arrow and then press to save your changes and exit The system is now configured Main Menu UPS Status UPS Configuration Display Date Time Event Log A...

Страница 13: ...environmentally responsible way that complies with local codes and regulations or return the module to Liebert for proper disposal CAUTION Battery modules are heavy 30 kg 66 lbs Make sure to use two...

Страница 14: ...lf way in slide the module sideways toward the center of the unit Continue pushing module until fully inserted 3 Press and turn fastener clockwise until locked 4 Wait about 15 seconds as the module pe...

Страница 15: ...3 73 149 221 293 7 000 4 900 8 16 23 30 36 43 50 57 78 161 245 329 6 500 4 550 9 17 24 32 40 47 55 62 84 174 258 342 6 000 4 200 11 19 24 36 43 51 60 68 92 190 286 382 5 500 3 850 12 21 23 39 47 56 66...

Страница 16: ...12...

Страница 17: ......

Страница 18: ...his literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2002 Liebert Corporation All...

Отзывы: