Contents

Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 | EN
General Information   . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Operating Constraints  . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Model Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Inspection and Storage . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Pump System Components  . . . . . . . . . . . . . . . . . . . . . 5 | EN
Wiring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 | EN
Preparation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 | EN
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 | EN
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 | EN
Maintenance and Troubleshooting . . . . . . . . . . . . . . . 9 | EN
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12 | EN

Safety Guidelines

Safety Precautions

Accidental contact with electrically live parts, items, fluid, or 

water can cause serious injury or death.

Always disconnect pump(s) from power source(s) before 

handling or making any adjustments to either the pump(s), 

the pump system, or the control panel.

All installation and maintenance of pumps, controls, 

protection devices, and general wiring shall be done by 

qualified personnel.

All electrical and safety practices shall be in accordance with 

the National Electrical Code

®

, the Occupational Safety and 

Health Administration, or applicable local codes and 

ordinances.

Do not remove cord and strain relief, and do not connect 

conduit to pump.

Pump shall be properly grounded using its supplied 

grounding conductor. Do not bypass grounding wires or 

remove ground prong from attachment plugs. Failure to 

properly ground the pump system can cause all metal 

portions of the pump and its surroundings to become 

energized.

Do not handle or unplug the pump with wet hands, when 

standing on damp surface, or in water unless wearing 

Personal Protective Equipment.

Always wear dielectric rubber boots and other applicable 

Personal Protective Equipment (PPE) when water is on the 

floor and an energized pump system must be serviced, as 

submerged electrical connections can energize the water. Do 

not enter the water if the water level is higher than the PPE 

protection or if the PPE is not watertight.

Do not lift or carry a pump or a float assembly by its power 

cord. This will damage the power cord, and could expose the 

electrically live wires inside the power cord.

The electrical power supply shall be located within the length 

limitations of the pump power cord, and for below grade 

installations it shall be at least 4 ft (1.22 m) above floor level.

Do not use this product in applications where human contact 

with the pumped fluid is common (such as swimming pools, 

fountains, marine areas, etc.).

Protect the power and control cords from the environment. 

Unprotected power and control (switch) cords can allow water 

to wick through ends into pump or switch housings, causing 

surroundings to become energized.

Do not use an extension cord to power the product. Extension 

cords can overload both the product and extension cord 

supply wires. Overloaded wires will get very hot and can catch 

on fire.

Do not use this product with or near flammable or explosive 

fluids such as gasoline, fuel oil, kerosene, etc. If rotating 

elements inside pump strike any foreign object, sparks may 

occur. Sparks could ignite flammable liquids.

This safety alert symbol is used in the manual 

and on the pump to alert of potential risk for 

serious injury or death.
This safety alert symbol identifies risk of 

electric shock. It is accompanied with an 

instruction intended to minimize potential 

risk of electric shock.
This safety alert symbol identifies risk of fire

It is accompanied with an instruction 

intended to minimize potential risk of fire.
This safety alert symbol identifies risk of 

serious injury or death. It is accompanied 

with an instruction intended to minimize 

potential risk of injury or death. 
Warns of hazards which if not avoided will 

result in serious injury or death.

Warns of hazards which if not avoided could 

result in serious injury or death.

Warns of hazards which if not avoided could 

result in minor or moderate injury.
Signals an important instruction related to 

the pump. Failure to follow these instructions 

could result in pump failure or property 

damage.

Read every supplied manual before using 

pump system. Follow all the safety instructions 

in manual(s) and on the pump. Failure to do 

so could result in serious injury or death.

RISK OF ELECTRIC SHOCK

RISK OF FIRE

Содержание XLE100 Series

Страница 1: ...rence For replacement manual visit LibertyPumps com or contact Liberty Pumps at 1 800 543 2550 Retain dated sales receipt for warranty Model 7000 Apple Tree Avenue Bergen NY 14416 ph 1 800 543 2550 fa...

Страница 2: ...res inside the power cord The electrical power supply shall be located within the length limitations of the pump power cord and for below grade installations it shall be at least 4 ft 1 22 m above flo...

Страница 3: ...te and Local codes and ordinances for hazardous locations All electrical terminations shall be made according to Federal State and Local codes for hazardous or classified locations Conduit junction bo...

Страница 4: ...complete If storage is necessary the pump should remain in its shipping container It should be stored in a warehouse or storage shed that has a clean dry temperature stable environment where the pump...

Страница 5: ...rly sized or adjusted for the full load input power indicated on the pump nameplate It is important to properly select and adjust the motor control overload protection The full load amperes on the nam...

Страница 6: ...e pump has cooled 1 phase models automatically reset after the pump has cooled to a safe temperature Power and Control Cords Do not remove cord and strain relief and do not connect conduit to pump The...

Страница 7: ...into the pump intake The pump can remain upright or can be laid down on its side for easier access to the intake Besides verification that the impeller is freely spinning rotating the impeller helps t...

Страница 8: ...skets and components are present Pump Record information from pump nameplate onto inside cover of these instructions Complete a visual inspection before lowering into basin Place pump in basin making...

Страница 9: ...further assistance To keep the pump pump system operating smoothly perform the following routine checks Monthly Pumps that are idle for more than a month in a dry basin should have impellers manually...

Страница 10: ...s trip Unintentional ground Turn off power and check motor leads for possible ground 3 phase motor winding failure Check resistance of motor windings All three phases should have the same reading Obst...

Страница 11: ...pen gate or ball valve Total head is beyond pump s capability Route piping to a lower level If not possible a larger pump may be required Consult Liberty Pumps Obstructed impeller or volute clogged in...

Страница 12: ...mages including costs of removal reinstallation or transportation There is no other express warranty All implied warranties including those of merchantability and fitness for a particular purpose are...