Liberty Pumps XLE100 Series Скачать руководство пользователя страница 9

3473000C

Copyright © Liberty Pumps, Inc. 2021 All rights reserved.

9 | EN

Maintenance and Troubleshooting

Accidental contact with electrically live parts, items, fluid, or 

water can cause serious injury or death.

Always disconnect pump(s) from power source(s) before 

handling or making any adjustments to either the pump(s), 

the pump system, or the control panel.

Do not enter a pump basin after it has been used. Sewage and 

effluent can emit several gases that are poisonous.

All electrical and motor repairs and service must be 

performed by a repair facility approved by Liberty Pumps and 

certified to work on explosion-proof motor enclosures.

Wear adequate Personal Protective Equipment when working 

on pumps or piping that have been exposed to wastewater. 

Sump and sewage pumps often handle materials that can 

transmit illness or disease upon contact with skin and other 

tissues.

Use only non-sparking tools and components in and around 

basins, open covers and vents. Do not use electronic devices 

that are not rated for use in hazardous locations or have live, 

exposed electrical circuits in or around basins, open covers 

and vents. Sewage and effluent systems produce and may 

contain flammable and explosive gases and sparks could 

ignite these gases. 

Verify proper 3-phase pump rotation before retuning to 

service.

 Maintenance

As the motor is oil-filled, no lubrication or other maintenance is 

required.
Some pumps come equipped with an air bleed hole to help 

prevent airlock. A small spray of water from this hole is normal 

while pump is running.
In the event the pump becomes clogged, the inlet screen can be 

removed to gain access to the pump impeller. Once the 

obstruction is removed, the anti-air lock hole should be cleaned.
Severe operating environments will require more frequent checks. 

For any issues that are not resolvable, contact Liberty Pumps for 

further assistance.

To keep the pump/pump system operating smoothly, perform the 

following routine checks:

 Monthly 

Pumps that are idle for more than a month in a dry basin should 

have impellers manually operated through the breaker panel 

monthly to lubricate the seals. 

Pumps that are idle in a wet basin 

must be removed.

 Quarterly 

1. Check pump(s) for corrosion and wear.
2. Check for free and unobstructed float switch operation and 

float switch condition.

3. Inspect for proper check valve operation.
4. For multiple pumps, check for balanced operating times. 

Uneven times indicate a defective unit, float switch or control.

5. Inspect the control panel for any presence of moisture in 

enclosure, loose connections, and general component 

condition.

 Annually 

1. Basin should be inspected and cleaned. Replace any defective 

components.

 Field Service on Hazardous Location Pumps 

The power and control cord are not field replaceable. If either cord 

is compromised, the entire pump must be brought to an 

authorized hazardous motor enclosure repair facility approved by 

Liberty Pumps.
The only allowable repair/replacement without compromising the 

hazardous location rating of the pump is the lower shaft seal 

replacement. A certified repair shop should perform this task since 

they have the capability to clean and flush the mid oil chamber.
Otherwise, the pump must be returned to Liberty Pumps or an 

authorized hazardous repair facility for electrical and motor 

service. This will ensure the integrity of the hazardous location 

rating of the pump and comply with Liberty Pumps warranty 

requirements.

 Troubleshooting

No repair work shall be carried out during the warranty period 

without prior factory approval. To do so may void the warranty.
Liberty Pumps, Inc. assumes no responsibility for damage or injury 

due to disassembly in the field. Disassembly, other than an 

authorized hazardous motor enclosure repair facility approved by 

Liberty Pumps or its authorized service centers, automatically 

voids warranty.

RISK OF ELECTRIC SHOCK

RISK OF SERIOUS INJURY OR DEATH

Содержание XLE100 Series

Страница 1: ...rence For replacement manual visit LibertyPumps com or contact Liberty Pumps at 1 800 543 2550 Retain dated sales receipt for warranty Model 7000 Apple Tree Avenue Bergen NY 14416 ph 1 800 543 2550 fa...

Страница 2: ...res inside the power cord The electrical power supply shall be located within the length limitations of the pump power cord and for below grade installations it shall be at least 4 ft 1 22 m above flo...

Страница 3: ...te and Local codes and ordinances for hazardous locations All electrical terminations shall be made according to Federal State and Local codes for hazardous or classified locations Conduit junction bo...

Страница 4: ...complete If storage is necessary the pump should remain in its shipping container It should be stored in a warehouse or storage shed that has a clean dry temperature stable environment where the pump...

Страница 5: ...rly sized or adjusted for the full load input power indicated on the pump nameplate It is important to properly select and adjust the motor control overload protection The full load amperes on the nam...

Страница 6: ...e pump has cooled 1 phase models automatically reset after the pump has cooled to a safe temperature Power and Control Cords Do not remove cord and strain relief and do not connect conduit to pump The...

Страница 7: ...into the pump intake The pump can remain upright or can be laid down on its side for easier access to the intake Besides verification that the impeller is freely spinning rotating the impeller helps t...

Страница 8: ...skets and components are present Pump Record information from pump nameplate onto inside cover of these instructions Complete a visual inspection before lowering into basin Place pump in basin making...

Страница 9: ...further assistance To keep the pump pump system operating smoothly perform the following routine checks Monthly Pumps that are idle for more than a month in a dry basin should have impellers manually...

Страница 10: ...s trip Unintentional ground Turn off power and check motor leads for possible ground 3 phase motor winding failure Check resistance of motor windings All three phases should have the same reading Obst...

Страница 11: ...pen gate or ball valve Total head is beyond pump s capability Route piping to a lower level If not possible a larger pump may be required Consult Liberty Pumps Obstructed impeller or volute clogged in...

Страница 12: ...mages including costs of removal reinstallation or transportation There is no other express warranty All implied warranties including those of merchantability and fitness for a particular purpose are...