Liberty Pumps ALM-P1 Скачать руководство пользователя страница 4

 

 

               

 

©Copyright 2012 Liberty Pumps Inc.    All rights reserved                                                   4 

 
 

Liberty Pumps, 3 Year Limited Warranty 

Liberty Pumps, Inc. warrants that pumps of its manufacture are free from all factory defects in material and workmanship for a period of 

3 years from the date of purchase.  The date of purchase shall be determined by a dated sales receipt noting the model and serial 

number of the pump.  The dated sales receipt must accompany the returned pump if the date or return is more than 3 years from the 

“CODE” (date of manufacture) number noted on the pump nameplate. 

The manufacturer’s obligation under this Warranty shall be limited to the repair or replacement of any parts found by the manufacturer 

to  be  defective,  provided  the  part  or  assembly  is  returned  freight  prepaid  to  the  manufacturer  or  its  authorized  service  center,  and 

provided that none of the following warranty-voiding characteristics are evident: 

The manufacturer shall not be liable under this Warranty if the product has not been properly installed; if it has been disassembled, 

modified, abused or tampered with;  if the electrical cord has been cut, damaged, or spliced;  if the pump discharge has been reduced 

in size;  if the pump has been used in water containing sand, lime, cement, gravel or other abrasives;  if the product has been used to 

pump chemicals or hydrocarbons;  if a non-submersible motor has been subjected to excessive moisture;  or if the label bearing the 

serial, model, and code number has been removed. 

Liberty  Pumps,  Inc.  shall  not  be  liable  for  any  loss,  damage  or  expenses  resulting  from  installation  or  use  of  its  products,  or  for 

consequential damages, including costs of removal, reinstallation or transportation. 

 

There is no other express warranty.  All implied warranties, including those of merchantability and fitness for a particular purpose, are 

limited to three years from the date or purchase. 

This warranty contains the exclusive remedy of the purchaser, and, where permitted, liability for consequential or incidental damages 

under any and all warranties are excluded. 

 
 
 

7000 Apple Tree Avenue 

Bergen, NY  14416 

Phone  800-543-2550 

www.libertypumps.com 

Содержание ALM-P1

Страница 1: ...n on when the bottom of the probes detect water The correct height for these probes should be above the turn on point of the pump and well below the top of the sump pit 3 Connect wires from water sens...

Страница 2: ...es The clamp should be placed on the intake pipe of the SJ10 pump with the bottom of the clamp touching the top of the pump s foot valve If the clamp is not positioned directly against the foot valve...

Страница 3: ...o 8 x 1 1 4 self tapping screws not included Use 8 plastic anchor if mounting to sheet rock See figure 5 3 If auxiliary contacts used continue otherwise go to step 4 Remove cover from base and remove...

Страница 4: ...if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been reduce...

Страница 5: ...tivar cuando la parte inferior de las sondas detecte agua La altura correcta para dichas sondas debe ser por encima del punto de encendido de la bomba y muy por debajo de la parte superior del sumider...

Страница 6: ...ivarse la bomba Hay que colocar la abrazadera en el tubo de entrada de la bomba SJ10 de manera que la parte inferior de la abrazadera toque la parte superior de la v lvula de aspiraci n de la bomba Si...

Страница 7: ...autorroscantes No 8 x 1 1 4 pulg no se incluyen Si monta la unidad sobre un panel de yeso utilice anclajes de pl stico No 8 Vea la Figura 5 3 Si se usan contactos auxiliares prosiga en caso contrario...

Страница 8: ...arant a El fabricante no tendr obligaci n alguna bajo esta garant a si el producto no ha sido instalado correctamente si ha sido desmontado modificado maltratado o forzado si el cable el ctrico se ha...

Страница 9: ...des d tectera de l eau Ces sondes doivent tre install es au dessus du niveau de mise en marche de la pompe et sous le haut du puisard 3 Raccorder les fils du capteur d eau au panneau d alarme Le fil r...

Страница 10: ...e tuyau d entr e de la pompe SJ10 le bas de la pince touchant le sommet du clapet de pied de la pompe Si la pompe n est pas plac e directement contre le clapet de pied l alarme risque de mal fonctionn...

Страница 11: ...1 po non comprises Utiliser les douilles d ancrage en plastique n 8 lors d une installation sur cloison s che Voir illustration 5 3 Poursuivre l installation si les contacts auxiliaires sont utilis s...

Страница 12: ...modifi soumis un usage abusif ou endommag si le cordon lectrique a t coup endommag ou ligatur si la taille du tuyau d vacuation de la pompe a t r duite si la pompe a t utilis e pour pomper de l eau d...

Отзывы: