Supplemental Installation Instructions for your ALM-P1 Alarm 

 

 

Product Description 

    

    The  ALM-P1  is  an  alarm  system  that  utilizes  a  water  sensor  connected  to  an  alarm  panel  to  detect  a  high  water 

situation in a sump pump application.  The sensor clamps on to 1-1/4” or 1-1/2” PVC pipe.  When water bridges the 

probes, the alarm box will activate an alarm light and horn.  The horn can be silenced by switching the rocker switch on 

the side.  The alarm light will still function even when the horn is silenced.   

 

Installation of the Water Sensor Probe on discharge pipe 

1.  The water sensor for the ALM-P1 was designed to be installed directly onto a pump discharge pipe.  The clamp will 

only fit onto 1-1/4” or 1-1/2” pipe.  See figures 1 and 2.   

2.  Determine correct height for the water sensor.  The alarm will turn on when the bottom of the probes detect water.  

The correct height for these probes should be above the turn on point of the pump and well below the top of the 

sump pit.   

3.  Connect wires from water sensor to the alarm panel.  Red wire must be connected to the “left” terminal, labeled 

R/W

.  The black wire must be connected to the “right” terminal, labeled 

B

.  Wire up to the panel can be secured to 

the pipe with the included zip tie. 

4.  Test the pump and the turn on level of the alarm.  When satisfied with the probe position, mark the level on the 

discharge pipe.  For added security, slide the probe clamp away from intended position and apply a small amount 

of PVC glue to the discharge pipe.   Return the alarm probe to desired position.  The PVC glue will bond the pipe 

and clamp to prevent accidental movement.   

5.

  To test the water sensor, immerse both probes in water or place a wet rag or sponge across the probes.  The 

alarm panel should activate.  Completely wipe and dry the probes before putting the unit back into service.

 

 
 
 
 
 
 
 
 
 
 
 

 

 

Probe level 

1-1/4” or 1-1/2” 

discharge 

Figure 1 

 

Figure 2 

1-1/4” or 1-1/2” 

discharge 

Probe level 

Содержание ALM-P1

Страница 1: ...n on when the bottom of the probes detect water The correct height for these probes should be above the turn on point of the pump and well below the top of the sump pit 3 Connect wires from water sens...

Страница 2: ...es The clamp should be placed on the intake pipe of the SJ10 pump with the bottom of the clamp touching the top of the pump s foot valve If the clamp is not positioned directly against the foot valve...

Страница 3: ...o 8 x 1 1 4 self tapping screws not included Use 8 plastic anchor if mounting to sheet rock See figure 5 3 If auxiliary contacts used continue otherwise go to step 4 Remove cover from base and remove...

Страница 4: ...if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been reduce...

Страница 5: ...tivar cuando la parte inferior de las sondas detecte agua La altura correcta para dichas sondas debe ser por encima del punto de encendido de la bomba y muy por debajo de la parte superior del sumider...

Страница 6: ...ivarse la bomba Hay que colocar la abrazadera en el tubo de entrada de la bomba SJ10 de manera que la parte inferior de la abrazadera toque la parte superior de la v lvula de aspiraci n de la bomba Si...

Страница 7: ...autorroscantes No 8 x 1 1 4 pulg no se incluyen Si monta la unidad sobre un panel de yeso utilice anclajes de pl stico No 8 Vea la Figura 5 3 Si se usan contactos auxiliares prosiga en caso contrario...

Страница 8: ...arant a El fabricante no tendr obligaci n alguna bajo esta garant a si el producto no ha sido instalado correctamente si ha sido desmontado modificado maltratado o forzado si el cable el ctrico se ha...

Страница 9: ...des d tectera de l eau Ces sondes doivent tre install es au dessus du niveau de mise en marche de la pompe et sous le haut du puisard 3 Raccorder les fils du capteur d eau au panneau d alarme Le fil r...

Страница 10: ...e tuyau d entr e de la pompe SJ10 le bas de la pince touchant le sommet du clapet de pied de la pompe Si la pompe n est pas plac e directement contre le clapet de pied l alarme risque de mal fonctionn...

Страница 11: ...1 po non comprises Utiliser les douilles d ancrage en plastique n 8 lors d une installation sur cloison s che Voir illustration 5 3 Poursuivre l installation si les contacts auxiliaires sont utilis s...

Страница 12: ...modifi soumis un usage abusif ou endommag si le cordon lectrique a t coup endommag ou ligatur si la taille du tuyau d vacuation de la pompe a t r duite si la pompe a t utilis e pour pomper de l eau d...

Отзывы: