Installation Instructions
Quick Start
1.
Connect HDBaseT Link
2.
Connect A/V sources
3.
Connect USB peripherals
4.
Connect display
5.
Connect audio (optional)
6.
Connect and configure control (optional)
7.
Apply power
Connect HDBaseT Link
TIA/EIA-568B
Orange/White
Orange
Green/White
Blue
Blue/White
Green
Brown/White
Brown
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
1
8
Connect a category cable from a compatible HDBaseT 2.0 transmitter HDBaseT output to the DL-HD2A-RX
receivers HDBaseT input.
HDBaseT Connection
Twisted Pair Wiring
Use TIA/EIA-568B wiring for Category 6
connection between the transmitter and
receiver
To ensure proper performance of the DL-HD2A-RX it is recommended that you use solid core
shielded Category 6 F/UTP cabling at a minimum. Category 5e F/UTP may perform well but
may not support power over HDBaseT reliably.
For optimized performance use the following Liberty Wire and Cable branded cabling;
Category 6 plenum;
24-4P-P-L6SH
Category 6A plenum;
24-4P-P-L6ASH
Category 6 NON-plenum;
24-4P-L6SH
Category 6A NON -plenum;
24-4P-L6ASH
When using shielded category cabling ALWAYS...
....use shielded connectors
....properly ground the category cable