background image

General programming
procedure with 55015 Univer-
sal Remote:
- Registers CV1 through CV4 can

be programmed directly by pro-
gramming the desired function
value in the register.

- To program higher CVs:

- In register CV6, input the num-

ber of the register you want to
program.

- Then input the desired function

value in register CV5.

Example:
Set hand-over function to ON
(program register CV54 to func-
tion value 3).
To program:
- Display shows “P --”
- Select register CV6 (press 6).
- Input 54 (register you want to

program).

- Execute programming (press

right arrow button).

- Display shows “P --”
- Select register CV5 (press 5).
- Input 3 (selected function value)
- Execute programming (press

right arrow button).

When programming with the
55045, all function values are pro-
grammed directly.

AUTHORIZED SERVICE

Improper service will void your
warranty. For quality service, con-
tact your authorized retailer or
one of the following LGB factory
service stations:

Ernst Paul Lehmann Patentwerk
Reparatur-Abteilung
Saganer Strasse 1-5
D-90475 Nürnberg
GERMANY
Telephone: (0911) 83707 0
Fax: (0911) 83707 70

LGB of America
Repair Department
6444 Nancy Ridge Drive
San Diego, CA 92121
USA
Telephone: (858) 535-9387
Fax: (858) 535-1091

You are responsible for any ship-
ping costs, insurance and cus-
toms fees.

Hint: Information on LGB prod-
ucts and LGB representatives

around the world is available
online at www.lgb.com

CAUTION! This model is not for
children under 8 years of age.
This model has small parts, sharp
parts and moving parts. Save the
supplied packaging and instruc-
tions.

Products, specifications and
availability dates are subject to
change without notice. Some
products are not available in all
markets and at all retailers. Some
products shown are pre-produc-
tion prototypes. LGB, LGB of
America, LEHMANN and the LGB
TOYTRAIN logotype are regis-
tered trademarks of Ernst Paul
Lehmann Patentwerk, Germany.
Other trademarks are the proper-
ty of their owners. © 2002 Ernst
Paul Lehmann Patentwerk.

13

Содержание VT 133 525

Страница 1: ...en an beiden Enden ausgestattet waren Damit er brigte sich ein Wenden des Fahrzeugs am Ende der Strecke Das brachte beim Betrieb auf Neben und Kurz strecken eine erhebliche Zeiter sparnis was zur Beli...

Страница 2: ...de cette garantie en particulier en cas de vice de mati re Pour initier une demande de r gle ment au titre de cette garantie veuillez ramener le produit avec la preuve d achat votre revendeur autoris...

Страница 3: ...Dachgep cktr ger und Leiter Fig 1 2 Power control switch Fig 3 Luggage rack and root walkways Illustr 1 2 Modes d exploitation IIllustr 3 Galerie partebagages et le chdles peuvent D 3 GB USA F 0 1 2...

Страница 4: ...der Lokadresse finden Sie in den Anleitungen der einzelnen MZS Regler Beim Betrieb mit dem Mehrzug system k nnen Funktionen der Lok ferngesteuert werden ber die Beleuchtungstaste 9 bei Handys wird di...

Страница 5: ...e ffnete T r greifen Dach von innen nach oben dr cken und abnehmen Vorsichtig die Lichtplatine von den Montagesockeln abziehen Gl hlampen austauschen Modell wieder zusammenbauen Ersatzteile 50019 Pfle...

Страница 6: ...ogrammierendes Register CV 29 Konfiguration 4 Normale Fahrtrichtung 4 Analog und Digital werks programm Fahrstufentabelle 0 nur Digital werkseitig programmierte Fahrstufentabelle 20 Analog und Digital...

Страница 7: ...t CV 61 Lastnachregelung Nachregelgeschwindigkeit 0 oft 255 selten 0 255 0 Legt fest wie oft pro Sekunde nachgeregelt wird ob die Lok auf Kurven und Steigungen sofort oder tr ge reagiert CV 62 Lastna...

Страница 8: ...IERTER SERVICE Bei unsachgem er Wartung wird Ihre Garantie ung ltig Um fachgerechte Reparaturleistun gen zu erhalten wenden Sie sich an Ihren Fachh ndler oder an die LGB Service Abteilung Ernst Paul L...

Страница 9: ...tion 3 Same as 2 but without taillights factory pre set Multi Train System The model is equipped a factory installed onboard decoder for the LGB Multi Train System It can be used without modifications...

Страница 10: ...an LGB factory service station see Authorized Ser vice Interior lights Remove the main roof panel by pushing up on the panel with a finger through an opening door Carefully pull the lighting circuit...

Страница 11: ...y user programmed speed steps Reversed direction 5 Analog and digital factory programmed speed steps 1 Digital only factory programmed speed steps 21 Analog and digital user programmed speed steps 17...

Страница 12: ...tely or with a short delay CV62 Back EMF Max Adjustment 0 small 255 max 0 255 255 Limits the total adjustment in motor voltage If there is a very large load on the motor the adjustment will not exceed...

Страница 13: ...he following LGB factory service stations Ernst Paul Lehmann Patentwerk Reparatur Abteilung Saganer Strasse 1 5 D 90475 N rnberg GERMANY Telephone 0911 83707 0 Fax 0911 83707 70 LGB of America Repair...

Страница 14: ...catalogue g n ral LGB pour des renseignements sur le programme LGB complet FONCTIONNEMENT Modes op ratoires Ce mod le est quip d un s lecteur d alimentation quatre positions situ sous le plancher fig...

Страница 15: ...ehmann Patentwerk et LGB of America ne sauraient tre tenus pour responsables pour quelque dommage que ce soit ENTRETIEN Entretien par l acheteur Niveau D butant Niveau Interm diaire Niveau Expert Atte...

Страница 16: ...fonction en utilisation normale Si la programmation ne donne pas de r sultats satisfaisants vous pouvez reprogrammer les valeurs attribu es par l usine aux principaux CV Programmer le registre CV55 l...

Страница 17: ...marche avant 4 analogique et num rique r glages de vitesse programm s par l usine 0 num rique uniquement r glages de vitesse programm s par l usine 20 analogique et num rique r glages de vitesse progr...

Страница 18: ...tit 255 grand Sp cifie l augmentation maximale ou la diminution maximale de la tension appliqu e pendant chaque intervalle de temps programm e dans CV61 Attention Les valeurs de CV60 et CV61 attribu e...

Страница 19: ...9 Conseil Les r glages de vitesse sont faits en usine et aucune programmation n est n cessaire Pour programmer les r glages de vitesse utiliser le module de programma tion de d codeur pour OP SMT 5504...

Страница 20: ...e et non avenue Veuillez entrer en contact avec votre revendeur ou avec l un des centres d entretien ci dessous Ernst Paul Lehmann Patentwerk Reparateur Abteilung Saganer Strasse 1 5 D 90475 N rnberg...

Страница 21: ...nt pas aux enfants de moins de 8 ans Pr sence de petits l ments susceptibles d tre aval s Attenzione Conservare l imballo e le istruzioni per l uso Non adatto a bambini di et inferiore agli 8 anni poi...

Отзывы: