14
Register Assignment
Range
Default
1
Address
1 – 127
3
2
Minimum speed
0 – 255
15
3
Acceleration delay
0 – 255
5
4
Braking delay
0 – 255
5
5
Maximum speed
0 – 255
255
8
Reset
8
131
13
Function F1 – F8 with alternative track signal
0 – 255
32
14
Function FL, F9 – F15 with alternative track signal
0 – 255
1
17
Expanded address, higher value byte
192 – 231
192
18
Expanded address, lower value byte
0 – 255
128
19
Multiple unit operation address
0 – 255
0
21
Functions F1 – F8 with multiple unit operation
0 – 255
0
22
Function FL, F9 – F15 with multiple unit operation
0 – 255
0
27
Bit 4: Braking mode voltage against the direction of travel
Bit 5: Braking mode voltage with the direction of travel
0/16
0/32
16
29
Bit 0: Direction normal/inverted
Bit 1: Number of speed levels 14/28(128)
Bit 2: Analog operation off/on
Bit 5: short / long address active
0/1
0/2
0/4
0/32
6
50
Alternative Formats
Bit 1: Analog DC
Bit 3: mfx off/on
0/2
0/8
10
53
Motor control – control reference
0 – 255
225
54
Motor control – control parameter K
0 – 255
64
55
Motor control – control parameter I
0 – 255
42
56
Motor control – control influence
0 – 255
26
57
steam chuff 1
0 – 255
1
58
steam chuff 2
0 – 255
0
Register Assignment
Range
Default
60
Multi-station announcement
Bit 0 – 3: Number of stations
Bit 4: Last announcement changes the sequence
Bit 5: Locomotive direction changes the sequence
Bit 6: Start for the sequence
0 – 15
0/16
0/32
0/64
1
63
Total volume
0 – 255
255
64
Threshhold for squealing brakes
0 – 255
55
67 – 94 Speed table for speed levels 1 – 28
0 – 255
112
Mapping lights in the front, mode
0 – 16
1
113
Mapping lights in the front, dimmer
0 – 255
255
114
Mapping lights in the front, cycle
0 – 255
20
115 – 135 Mapping phys. outputs, lights in the rear, Aux 1 – 6,
compare 112 – 114
0 – 16
0 – 255
137
Factor for switching range
1 – 128
128
138
Volume for squealing brakes
0 – 255
255
139
Volume for Operating sounds
0 – 255
255
140
Volume for Horn
0 – 255
255
141
Volume for Horn
0 – 255
255
142
Volume for Station announcements
0 – 255
255
143
Volume for Station announcements
0 – 255
255
150
Volume for Air pump
0 – 255
255
152
Volume for Compressed air
0 – 255
255
153
Volume for sanding
0 – 255
255
176
Minimum speed in analog DC
0 – 255
10
177
Maximum speed in analog DC
0 – 255
255
257 – 260 Function mapping Function FL forwards
0 – 255
257 = 1
262 – 265 Function mapping Function F1 forwards
0 – 255
263 = 16