background image

10

INSTALLATION

INSTALLATION

How to Install the Unit

1

Measure the wall sleeve and air conditioner di-
mensions.
You can install the new air conditioner according
to these installation instructions to achieve the
best performence. All wall sleeves used to
mount the new air conditioner must be in good
structural condition and have the rear grille(sold
separately) that securely gets attached to the
sleeve or the flange of the sleeve to secure the
new air conditioner.

Dimension of air conditioner

Dimension of sleeve assembly (optional)

2

To avoid vibration and noise, make sure the unit
is installed securely and firmly.

3

When installing the sleeve & Front grille, make
certain there is nothing within 21” back & front of
sleeve & front grille, that would interfere with
heat radiation and exhaust air flow.

4

An insulation strip must be attached. 

The insulation strip is provided with the box.

5

After assembly of sleeve & front grille, the gap

should be over 20” from both sleeve & grille. 
(See the figure 1.)

Figure 1

6

Take out the insulation strip from the upper
packing.

7

Attach the insulation strip onto the rear upper

side of the wall sleeve.

406 mm

(16")

1,066 mm 

(42")

349 mm

(13 

3

/

4

") 

536 mm

(21")

406 mm

(16")

1066 mm

(42")

349 mm
(13 

3

/

4

")

Insulation

Joint Gap

Over 20"

HEAT

RADIATION

WALL

WALL

INSULATION

SLEEVE

INTAKE
AIR

COOLED
AIR

1/4" Bubble 
of the level

Over 20"

Front

Insulation Strip

Rear

Sleeve

280 mm 

(11")

CAUTION

• Require 2 people to lift the air conditioner,

it is HEAVY

• Before installation, Check the insulation on

the inner side of the sleeve. If there is no
insulation, place the insulation.

• Check the bottom corner's joint gap of the

sleeve, If there is, fill the gap with putty.

!

Содержание Y4NV07ANLK0.AK3GEUS

Страница 1: ...ectronics Inc All Rights Reserved MFL67646805 Rev 04_111120 OWNER S MANUAL AIR CONDITIONER Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times ENGLISH FRANÇAIS ESPAÑOL TYPE ROOM AIR CONDITIONER ...

Страница 2: ... cord 12 Disassembly Instructions 12 Electrical Data 14 Electrical Safety 15 Subbase Optional 17 OPERATION 17 Before Operation 18 Manual Controls 19 Control Panel 20 Additional Controls 25 Self Diagnosis 27 SMART FUNCTIONS 27 LG ThinQ Application 29 Smart Diagnosis 30 MAINTENANCE 30 Air Filter 31 Vent Filter 32 Unit 32 Compressor and Fan Motor 32 Front Grille 33 TROUBLESHOOTING 33 Before Calling f...

Страница 3: ...NING To reduce the risk of explosion fire death electric shock scalding or injury to persons when using this product follow basic precautions including the following California Proposition 65 This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling INSTALLATION Before use the appliance must be properly i...

Страница 4: ... to outdoor weather conditions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not install the unit in potentially explosive atmospheres OPERATION The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air condition...

Страница 5: ...g Use this with a standard three slot grounding wall power outlet to minimize the hazard of electric shock The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded DO NOT CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER PLUG Situations when the appliance will be disconnected occasionally Because of potential saf...

Страница 6: ...o pinch crush or damage the power cord Make sure the air inlet and outlet are free from obstructions Use a soft cloth to clean the appliance Do not use waxes thinners or harsh detergents Do not step on or place heavy objects on top of the appliance Do not operate the appliance without the filter securely installed Do not drink water drained from the appliance Be sure to ventilate sufficiently when...

Страница 7: ...etter performance in PTAC and PTHP Units For Installation purpose and better appearance Aluminum Rear Grille or Architecture Rear Grille can be applied in PTAC and PTHP Units I N D O O R ALUMINUM REAR GRILLE Option ARCHITECTURE REAR GRILLE Option EXPANDED METAL GRILLE Option SLEEVE ASSEMBLY Option FRONT GRILLE Air Intake AIR FILTER VERTICAL AIR DEFLECTOR Horizontal Louver Air Outlet ...

Страница 8: ...Grill Door Mesh Metal Fan Cover Brace Shroud Fan Control Box Compressor Base pan Bracket Pan drain Evaporator Vent Door Rear Grille Condenser Valve Drain 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 20 2 5 10 11 12 13 14 15 16 3 4 6 7 8 9 19 18 17 ...

Страница 9: ...TALLATION 9 ENGLISH PREPARING FOR INSTALLATION Contents of Installation Kit Tools and Materials Needed Screws 6 Wall thermostat harness Wire Nuts 7 Insulation Strip Phillips head screwdriver Utility Knife Nipper pliers ...

Страница 10: ...t grille that would interfere with heat radiation and exhaust air flow 4 An insulation strip must be attached The insulation strip is provided with the box 5 After assembly of sleeve front grille the gap should be over 20 from both sleeve grille See the figure 1 Figure 1 6 Take out the insulation strip from the upper packing 7 Attach the insulation strip onto the rear upper side of the wall sleeve...

Страница 11: ...nd screw ELECTRIC HEATER RATING CONFIGURATION BASED ON POWER CORD 4 Replace cover with screws Tighten securely 5 Slide the unit into the wall sleeve and secure with 4 screws through the unit flange holes 6 Reinstall the front grille by hooking the top over the unit top then pushing it in at the bottom POWER CORD VOLTAGE HEATER WATTS HEATER CURRENT MAX FUSE SIZE MIN CIR CUITAM PACITY AYUH2315 230 2...

Страница 12: ...n angle of 15 off vertical To adjust the air direction remove the front grille Remove the 4 screws that fasten the discharge grille to the front grille Rotate the discharge grille 180 then assembly the discharge grille to the front grille with 4 screws Electrical Data Power cord may include a current interrupter device TEST and RESET buttons are provided on the plug case The device should be teste...

Страница 13: ...nce with the National Electrical Code Use of extension cords could cause serious injury or death Do not use an extension cord with this air conditioner Do not use surge protectors or multi outlet adapters with this air conditioner Never push the TEST button during operation Doing so can damage the plug Do not remove modify or immerse this plug If this device trips the cause should be corrected bef...

Страница 14: ... in the receptacle to assure a proper polarity con nection Disconnect the power cord from the adapter using one hand on each Otherwise the adapter ground terminal might break DO NOT USE the appliance with a broken adapter plug B SITUATIONS WHEN THE APPLIANCE WILL BE DISCONNECTED OFTEN Do not use an adapter plug in these situations Un plugging the power cord frequently can lead to an eventual break...

Страница 15: ...nstal lation Also the subbase is pre wired and is grounded by means of a grounding screw Part No AYSB1201B Subbase 208 230V 20A w o DS AYSB1301B Subbase 208 230V 30A w o DS AYSB5101 Subbase Panel AYSB6101 Subbase Non Electrical Notes w o DS without disconnect switch w DS with disconnect switch NOTE When using a subbase the wall sleeve must be installed at a minimum height of 3 1 4 inches 83mm abov...

Страница 16: ...uts for conduit con nections 6 Take electrical junction box cover off and use field supplied wire nuts to connect power to receptacle wires See Figure 3 7 Attach subbase to wall sleeve Subbase has side tabs for mounting the subbase to sleeve Be sure hole on the side tab is lined up with the pre drilled hole on side of sleeve Once holes are aligned attach subbase to sleeve with one one screw on eac...

Страница 17: ...possibility of oxygen deficiency venti late the room when used together with stoves or other heating devices Do not use this air conditioner for non specified special purposes e g preserving precision de vices food pets plants and art objects Such usage could damage the items Cleaning and Maintenance Do not touch the metal parts of the unit when re moving the filter Injuries can occur when handlin...

Страница 18: ...t switching to HEAT after the cooling season is over This odor caused by fine dust particles on the heater will disappear quickly This is harmless CAUTION When the air conditioner has been running and is turned off or set to the fan position wait at least 3 minutes before resetting to the cooling heating operations CAUTION PTAC exhausting discharge air in balcony that is closed off with glass or p...

Страница 19: ... Fan Speed button to set the desired fan circulation speed Fan In this mode the fan circulates air but the compressor does not run Use the Fan Speed button to set fan speed to High Medium Low or Slow In this mode you cannot adjust the set temperature Dry This mode is ideal for rainy and damp days to dehumidify the room rather than cooling it significantly Moisture is removed from the room by the c...

Страница 20: ...ot available on all models Control Type 1 0 Local Wifi LG Exclusive Wired Remote Controller option Default setting 1 Remote Energy Saver 2 0 Off Default setting 1 On Temperature Display 3 0 Fahrenheit Default setting 1 Celsius Cooling Heating Temperature Limit 4 0 54 F 12 2 C 86 F 30 0 C 54 F 12 2 C 86 F 30 0 C Default setting 1 56 F 13 3 C 86 F 30 0 C 54 F 12 2 C 84 F 28 9 C 2 58 F 14 4 C 86 F 30...

Страница 21: ...rovide continuous fan oper ation in cool or heat modes When Energy Saver mode is off the continuous fan allows continuous circu lation of room air and make the more balanced temperature of the room When Energy Saver mode is on the fan is on or off with the compressor or with the heater Press the pad to turn on Energy Saver mode The default setting for Mode 2 is off MODE 3 Temperature Display Press...

Страница 22: ...ric Heater and Heat Pump type MODE 6 Make Up Air Mode Option Press MODE until a 6 appears in the first digit of the display for Make Up Air mode Press the or pad to change 2nd Digit number The default setting for Mode 6 is off 2nd Digit Cooling Heating 0 54 F 12 2 C 86 F 30 0 C 54 F 12 2 C 86 F 30 0 C 1 56 F 13 3 C 86 F 30 0 C 54 F 12 2 C 84 F 28 9 C 2 58 F 14 4 C 86 F 30 0 C 54 F 12 2 C 82 F 27 8...

Страница 23: ...l thermostat When the wires are connected the unit will be controlled by a remote wall thermostat The thermostat connections supply the 24 Volt AC When you install the digital electronic thermostat you must set it to 24 Volt AC Molex Housing Spec 396 07V NOTICE For wiring connection of Wall Thermostat check the Installation instruction or Installation manual s provided by Thermostat Company Wire A...

Страница 24: ...it Model PQRCHCSA NOTICE For wiring connection of SIMPLE WIRED REMOTE CONTROLLER check the Installation instruction or Installation manual s provided by LG company accessory kit Model PQRCHCSA Indoor Unit side C Box PCB C BOX Cable Plug type Remote controller PCB The back side TEMP FAN SPEED OPER MODE BLACK GND RED 12V YELLOW Signal Signal Yellow 12V Red GND Black Type B screw Option Connecting Ca...

Страница 25: ...as follows Electrical Controls Error Code Descriptions 01 Indoor unit room temperature sensor error 02 Indoor unit inlet pipe sensor error 03 Wired remote control error 05 Communication error between indoor and outdoor units 07 Thermostat Wiring Error 09 Indoor unit EEPROM error 10 Indoor unit BLDC motor fan lock 21 DC Peak IPM Fault 22 CT 2 Max CT 23 DC Link Low Volt 26 DC Comp Position Error 27 ...

Страница 26: ...over heating of unit by elec trical heater located inside of the unit at the re mote mode when the unit is connected with wall thermostat Freeze Protection This feature prevents freezing of room at low tem perature Remote Mode When use the remote mode operation NOTICE 26 OPERATION ...

Страница 27: ...g time to reg ister or installation may fail 2 Turn off the Mobile data or Cellular Data on your smartphone 3 Connect your smartphone to the wireless router NOTE To verify the Wi Fi connection check that icon on the control panel is lit The appliance supports 2 4 GHz Wi Fi networks only To check your network frequency contact your Internet service provider or refer to your wire less router manual ...

Страница 28: ...rt phone Follow instructions to download and install the application How to connect Wifi Module 1 To remove the front grille pull out the bottom of the front grille and then lift up 2 Remove two covers by removing 4 screws Con nect accessory Wifi module option to the Wifi PCB behind Control box panel You need to purchase additional accessory Wifi module to install this unit When connecting a Wi Fi...

Страница 29: ...he in structions provided in the LG ThinQ application Using Audible Diagnosis to Diagnose Issues Follow the instructions below to use the audible di agnosis method Launch the LG ThinQ application and select the Smart Diagnosis feature in the menu Follow the instructions for audible diagnosis provided in the LG ThinQ application 1 Plug the power plug in the outlet properly 2 Place the mouthpiece of...

Страница 30: ...r grille The Front Grille and discharge air grille can be cleaned with a mild soap or detergent Under no circumstances should hydrocarbon based cleaners e g acetone benzene naphtha gasoline etc be used to clean the front or air grilles Use care when cleaning the control area Do not use an excessively wet cleaning cloth NOTE To ensure continued peak efficiency the condenser coils outside of unit sh...

Страница 31: ...th a Phillips Head screwdriver 3 Slide the unit out of the wall sleeve far enough so that the vent filter is accessible as shown in Figure A Remove the shipping screw from the ventilation door Figure A 4 Remove the vent filter by unscrewing the two screws at the top of the filter and gently pulling the filter away from the partition panel Refer to Figure B Figure B 5 Wash the filter using lukewarm...

Страница 32: ...lean the coils but make sure to cover the control with a blanket or plastic bag to keep it dry Compressor and Fan Motor The compressor and fan motor are hermetically sealed permanently lubricated and require no addi tional oiling Front Grille The Front Grille and discharge air grille can be cleaned with a mild soap or detergent Under no cir cumstances should hydrocarbon based cleaners e g acetone ...

Страница 33: ...s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal op eration Vibration Unit may vibrate and make noise because of poor wall or window constructio...

Страница 34: ... heat up cool down Cold air is escaping Check for open furnace floor registers and cold air returns Hot air is escaping Make sure that all vents are closed to air returns Cooling coils have iced up See Air conditioner freezing up below Air conditioner freezing up The cooling coils are iced over Ice may block the air flow and obstruct the air conditioner from properly cooling the room Set the mode ...

Страница 35: ...ing the Wi Fi network The wireless network name SSID is set incorrectly The wireless network name SSID should be a combination of English letters and numbers Do not use special characters The router frequency is not 2 4 GHz Only a 2 4 GHz router frequency is supported Set the wireless router to 2 4 GHz and connect the appliance to the wireless router To check the router frequency check with your I...

Страница 36: ... demand to LG at LG Electronics USA Inc Attn Legal Department Arbitration 111 Sylvan Avenue Englewood Cliffs NJ 07632 If there is a conflict between the AAA Rules and the rules set forth in this section the rules set forth in this section will govern This arbitration provision is governed by the Federal Arbitration Act Judgment may be entered on the arbitrator s award in any court of competent jur...

Страница 37: ... in small claims court but that small claims court action may not be brought on a class or representative basis except to the extent this prohibition is not permitted at law in your province or territory of jurisdiction as it relates to the claims at issue between you and LG Arbitration Rules and Procedures arbitration The arbitration will be private and confidential and conducted on a simplified ...

Страница 38: ...hall control and govern the rights and obligations of the parties and shall take precedence over the EULA In the event that you Opt Out the law of the province or territory of your residence shall govern this Limited Warranty and any disputes between you and LG except to the extent that such law is preempted by or inconsistent with applicable federal or provincial territorial law Should arbitratio...

Страница 39: ......

Отзывы: