ENGLISH
Installation Manual
5
Installation of Indoor, Outdoor Unit
Installation of Indoor, Outdoor Unit
1. Selection of the best location
1) Indoor unit
• There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent
the air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, or other obstacles.
2) Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure that
heat flow from the condenser is not restricted.
• Ensure that the space around the back and
sides is more than 300mm. The front of the unit
should have more than 700mm of space.
• Do not place animals and plants in the path of
the warm air.
• Take the weight of the air conditioner into
account and select a place where noise and
vibration are minimum.
• Select a place where the warm air and noise
from the air conditioner do not disturb neighbors.
More than
200mm
More than
1200mm
More than
200mm
R
R
More than
200mm
More than
200mm
(Ceiling installation)
(Floor/Wall installation)
More than
300mm
More than 300mm
More
than 600mm
More than 600mm
More than
700mm
More than
700mm
More than
300mm
More than
700mm
VB CHASSIS
VK,VJ,VL CHASSIS