Convertible Air Conditioner
Connecting Cables between Indoor Unit and Outdoor Unit
Connecting Cables between Indoor Unit and Outdoor Unit
R
AIR GUIDE-L
INDOOR UNIT
Control
Panel
1
2
Clamp
• Cooling Model Only
1(L) 2(N) 1(L) 2(N) 3
4
Terminals on the indoor unit
Power Input
Terminals on the outdoor unit
1(L) 2(N)
3
4
5
• Heat Pump Model Only
1(L) 2(N) 1(L) 2(N) 3
4
Terminals on the indoor unit
Power Input
Terminals on the outdoor unit
1(L) 2(N)
3
4
5
The power cord
connected to the indoor
unit should be complied with the following
specifications (Type H05VV-F(Indoor)
approved by HAR or SAA).
The power connecting cable
connected between the indoor
and outdoor unit should be
complied with the following
specifications
(Type H07RN-F approved by
HAR or SAA).
•
•
•
•
20mm
GN/YL
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2
(18k/24k/28k)
Cooling Only
Heat Pump
4 x 0.75
(Including Earth)
5 x 0.75
(Including Earth)
CAUTION
1) Connecting cables to the Indoor Unit
1) Remove the Air guide - L by loosening 2 screws
after removing the Inlet grille from the Indoor unit.
2) Connect the wires to the terminals on the control
board individually according to the outdoor unit
connection.
• Ensure that the color of the wires of outdoor unit and
the terminal No. are the same as those of indoor unit
respectively
2) Clamping of cables
1) Arrange the connecting cable on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly.
For the heat pump model, put the 0.75mm
2
cable(thinner cable) on the clamp and tighten it with a plastic
clamp to the other boss of the control panel.
4) In Australia, the length of power supply cord measured from the entry of the power supply cord to the middle
of live pin on the power plug should be over 1.8m.