SAFETY INSTRUCTIONS
9
ENGLISH
• Do not touch leaked refrigerant directly.
- There is risk of frostbite.
• Copper in contact with refrigerants shall be oxygen-free or
deoxidized, for example Cu-DHP as specified in EN 12735-1
and EN 12735-2.
• Compliance with national gas regulations shall be observed.
(for R32)
• Refrigerant tubing shall be protected or enclosed to avoid
damage. (for R32)
• The installation of pipe-work shall be kept to a minimum. (for
R32)
• A brazed, welded, or mechanical connection shall be made
before opening the valves to permit refrigerant to flow
between the refrigerating system parts. A vacuum valve shall
be provided to evacuate the interconnecting pipe and/or any
uncharged refrigerating system part. (for R32)
• Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an
industry-accredited assessment authority, which authorises
their competence to handle refrigerants safely in accordance
with an industry recognised assessment specification. (for
R32)
• Do not use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
(for R32)
• Do not pierce or burn. (for R32)
• Be aware that refrigerants may not contain an odour. (for R32)
• Dismantling the unit, treatment of the refrigerant oil and
eventual parts should be done in accordance with local and
national standards. (for R32)
• Flexible refrigerant connectors (such as connecting lines
between the indoor and outdoor unit) that may be displaced
during normal operations shall be protected against mechanical
damage. (for R32)