31
GENERAL INFORMATION
ENGLISH
No
Name
Remark
1
Leaving Water Pipe
Male PT 1 inch
2
Entering Water Pipe
Male PT 1 inch
3
Refrigerant Pipe
Ø 9.52 mm
4
Refrigerant Pipe
Ø 15.88 mm
5
Water Pump
Circulating the water
6
Safety Valve
Open at water pressure 3 bar
7
Control Box
PCB and terminal blocks
8
Thermal switch
Cut-off power input to electric heater at 90 °C
(manual return at 55 °C)
Cut-off power input to electric heater at 184 °C
(Not Recoverable)
9
Flow Sensor
Range : 7 ~ 80 L/min
10
Plate Heat Exchanger
Heat exchange between refrigerant and water
11
Pressure Gauge
Indicates circulating water pressure
12
Expansion Tank
Absorbing Volume change of heated water
13
Air Vent
Air purging when Charging water
14
Electric Heater
Please refer to the below Page
‘Model name and related information’
Cut-off power input to electric heater at 184 °C
(Not Recoverable)
15
Strainer
Filtering and stacking particles inside circulating water
16
Shut-off valve
To drain or to block water when pipe connecting
Description
Содержание THERMA V