![LG THERMA V HM051MR Скачать руководство пользователя страница 261](http://html.mh-extra.com/html/lg/therma-v-hm051mr/therma-v-hm051mr_installation-manual_213287261.webp)
261
COMMISSIONING
ENGLISH
Vacuum & Charge of Refrigerant
By default, the product was charged of refrigerant.
Vacuum and refrigerant charge, If there is leak refrigerant.
1. Vacuum
To work of vacuum action. when the leak of refrigerant.
Vacuum pump
(0.5 ~ 1 HP)
Lo
Hi
Manifold valve
Pressure
gage
Open
Close
SVC Port
Manifold gage
When selecting a vacuum, you should select one which is capable of achieving 0.2 Torr of
ultimate vacuum.
※
0 Pa
(gage)
=1 atm=760 Torr=760 mmHg=1 013.25 hPa
Unit
Standard atmospheric
pressure
Perfect vacuum
Gage Pressure
Pa
0
-1.033
Absolute Pressure
kgf / cm
2
1.033
0
* The feature may be vary according to the type of model.