192
INSTALLER SETTING
ENGLISH
Segmentation
Functions
Description
Connectivity
Dry Contact Mode
Dry contact function is the function that can be
used only when the dry contact devices is
separately purchased and installed.
Central Control Address
When connecting the central control, set the
central control address of the unit.
CN_CC
It is the function to set whether to install (use) Dry
Contact. (It is not a function for Dry Contact
installation, but it is a function to set the usage of
the unit’s CN_CC port.)
CN_EXT
Function to set external input and output control
according to DI / DO set by customer using dry
contact port of indoor unit. Determine the use of
the contact port (CN_EXT) mounted on the indoor
unit PCB
3rd Party Boiler
Configuration to control 3rd party boiler
Meter Interface
When installing the meter interface to measure
energy / calorie in the product, set unit spec for
each port
Energy state
Select whether to use or not use the SG Mode
function of the product, set the operation option
value in SG1 step.
Thermostat control type
Setting Thermostat control type
Modbus Address
It is function to set the address of the Modbus
device that is externally linked to the product.
Modbus address setting function is available from
indoor unit.
Info
Pump operation time
Display water pump's operation time
IDU operation time
Display Indoor Unit's operation time
Current Flow Rate
Function to check the current flow rate.
Data logging
Display error and operation history of connected
unit