Heat Pump Water Heater
-
5
0 Hz ( R134a)
4
3
1
7
.
Maintenance
Shut-down for an Extended
Period
If the water heater will not be used for an
extended period of time, turn off the power
and water supply to water heater and drain
water heater to conserve energy and prevent
a build-up of dangerous hydrogen gas.
The water heater and piping should be drained
if they might be subjected to freezing
temperature.
After a long shutdown period, the water
heater’s operation and controls should be
checked by qualified service personnel. Make
certain the water heater is completely filled
again before placing it in operation.
Condensate Drain
Maintenance
1
Remove the condensate drain lines and
connections.
ڸ
ڹ
ں
2
Pull the front decor first, and then remove
the top cover. Lift the front panel out, then
slightly lift the rear panel and remove it.
3
Check the condensate drain pan for any
debris, and clean the condensate drain by
wiping out with a damp cloth or pouring a
cup of bleach.
4
Reattach top cover and side panel and
connect the condensate drain line.
5
Restore power to the water heater.