6
ENGLISH
Unit
2 Outdoor Unit
HP
32
34
36
Model Name
Combination Unit
ARUB320DTE4
ARUB340DTE4
ARUB360DTE4
Independ-
ent Unit
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB120DTE4
ARUB140DTE4
ARUB160DTE4
Refigerant charging
amount
kg
lbs
10.7 × 1 + 7.7 × 1
10.7 × 2
10.7 × 2
Number of maxmum connectable indoor units 23.6 × 1 + 16.9.0 × 1
23.6 × 2
23.6 × 2
Net Weight
kg
52(64)
55(64)
58(64)
lbs
285 × 1 + 208 × 1
285 × 1 + 245 × 1
285 × 1 + 245 × 1
Dimensions
(WxHxD)
mm
628 × 1 + 459 × 1
628 × 1 + 540 × 1
628 × 1 + 540 × 1
inch
(1,240×1,680×760)×1
+ (920×1,680×760)×1
(1,240×1,680×760)×2 (1,240×1,680×760)×2
Pipe
Connc-
tions
Liquid Pipes mm(inch)
(48.8×66.1×29.9)×1
+(36.2×66.1×29.9)×1
(48.8×66.1×29.9)×2
(48.8×66.1×29.9)×2
Low Pressure Gas Pipes mm(inch)
19.05(3/4)
19.05(3/4)
19.05(3/4)
High Pressure Gas Pipes mm(inch)
34.9(1 3/8)
34.9(1 3/8)
41.3(1 5/8)
Unit
3 Outdoor Unit
HP
56
58
60
Model Name
Combination Unit
ARUB560DTE4
ARUB580DTE4
ARUB600DTE4
Independ-
ent Unit
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB160DTE4
ARUB180DTE4
ARUB200DTE4
Refigerant charging
amount
kg
lbs
10.7 × 3
10.7 × 3
10.7 × 3
Number of maxmum connectable indoor units
23.6 × 3
23.6 × 3
23.6 × 3
Net Weight
kg
64
64
64
lbs
285 × 2 + 208 × 1
285 × 3
285 × 3
Dimensions
(WxHxD)
mm
628 × 2 + 540 × 1
628 × 3
628 × 3
inch
(1,240×1,680×760)×3 (1,240×1,680×760)×3 (1,240×1,680×760)×3
Pipe
Connc-
tions
Liquid Pipes mm(inch)
(48.8×66.1×29.9)×3
(48.8×66.1×29.9)×3
(48.8×66.1×29.9)×3
Low Pressure Gas Pipes mm(inch)
19.05(3/4)
19.05(3/4)
19.05(3/4)
High Pressure Gas Pipes mm(inch)
41.3(1 5/8)
41.3(1 5/8)
41.3(1 5/8)
Unit
4 Outdoor Unit
HP
62
64
66
Model Name
Combination Unit
ARUB620DTE4
ARUB640DTE4
ARUB660DTE4
Independ-
ent Unit
ARUB180DTE4
ARUB180DTE4
ARUB180DTE4
ARUB160DTE4
ARUB180DTE4
ARUB180DTE4
ARUB140DTE4
ARUB140DTE4
ARUB160DTE4
Refigerant charging
amount
kg
ARUB140DTE4
ARUB140DTE4
ARUB140DTE4
lbs
10.7 x 4
10.7 x 4
10.7 x 4
Number of maxmum connectable indoor units
23.6 × 4
23.6 × 4
23.6 × 4
Net Weight
kg
64
64
64
lbs
285 × 1 + 245 × 3
285 × 2 + 245 × 2
285 × 2 + 245 × 2
Dimensions
(WxHxD)
mm
628 × 1 + 540 × 3
628 × 2 + 540 × 2
628 × 2 + 540 × 2
inch
(1,240×1,680×760)×4 (1,240×1,680×760)×4 (1,240×1,680×760)×4
Pipe
Connc-
tions
Liquid Pipes mm(inch)
(48.8×66.1×29.9)×4
(48.8×66.1×29.9)×4
(48.8×66.1×29.9)×4
Low Pressure Gas Pipes mm(inch)
22.2(7/8)
22.2(7/8)
22.2(7/8)
High Pressure Gas Pipes mm(inch)
44.5(1 3/4)
44.5(1 3/4)
53.98(2 1/8)
Unit
4 Outdoor Unit
HP
68
70
72
Model Name
Combination Unit
ARUB680DTE4
ARUB700DTE4
ARUB720DTE4
Independ-
ent Unit
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB140DTE4
ARUB160DTE4
ARUB180DTE4
Refigerant charging
amount
kg
ARUB140DTE4
ARUB140DTE4
ARUB140DTE4
lbs
10.7 x 4
10.7 x 4
10.7 x 4
Number of maxmum connectable indoor units
23.6 × 4
23.6 × 4
23.6 × 4
Net Weight
kg
64
64
64
lbs
285 × 2 + 245 × 2
285 × 2 + 245 × 2
285 × 3 + 245 × 1
Dimensions
(WxHxD)
mm
628 × 2 + 540 × 2
628 × 2 + 540 × 2
628 × 3 + 540 × 1
inch
(1,240×1,680×760)×4 (1,240×1,680×760)×4 (1,240×1,680×760)×4
Pipe
Connc-
tions
Liquid Pipes mm(inch)
(48.8×66.1×29.9)×4
(48.8×66.1×29.9)×4
(48.8×66.1×29.9)×4
Low Pressure Gas Pipes mm(inch)
22.2(7/8)
22.2(7/8)
22.2(7/8)
High Pressure Gas Pipes mm(inch)
53.98(2 1/8)
53.98(2 1/8)
53.98(2 1/8)
Unit
4 Outdoor Unit
HP
74
76
Model Name
Combination Unit
ARUB740DTE4
ARUB760DTE4
Independ-
ent Unit
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB180DTE4
ARUB180DTE4
Refigerant charging
amount
kg
ARUB160DTE4
ARUB180DTE4
lbs
10.7 x 4
10.7 x 4
Number of maxmum connectable indoor units
23.6 × 4
23.6 × 4
Net Weight
kg
64
64
lbs
285 × 3 + 245 × 1
285 × 4
Dimensions
(WxHxD)
mm
628 × 3 + 540 × 1
628 × 4
inch
(1,240×1,680×760)×4
(1,240×1,680×760)×4
Pipe
Connc-
tions
Liquid Pipes mm(inch)
(48.8×66.1×29.9)×4
(48.8×66.1×29.9)×4
Low Pressure Gas Pipes mm(inch)
22.2(7/8)
22.2(7/8)
High Pressure Gas Pipes mm(inch)
53.98(2 1/8)
53.98(2 1/8)
Unit
4 Outdoor Unit
HP
78
80
Model Name
Combination Unit
ARUB780DTE4
ARUB800DTE4
Independ-
ent Unit
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
Refigerant charging
amount
kg
ARUB180DTE4
ARUB200DTE4
lbs
10.7 x 4
10.7 x 4
Number of maxmum connectable indoor units
23.6 × 4
23.6 × 4
Net Weight
kg
64
64
lbs
285 × 4
285 × 4
Dimensions
(WxHxD)
mm
628 × 4
628 × 4
inch
(1,240×1,680×760)×4
(1,240×1,680×760)×4
Pipe
Connc-
tions
Liquid Pipes mm(inch)
(48.8×66.1×29.9)×4
(48.8×66.1×29.9)×4
Low Pressure Gas Pipes mm(inch)
22.2(7/8)
22.2(7/8)
High Pressure Gas Pipes mm(inch)
53.98(2 1/8)
53.98(2 1/8)
Unit
2 Outdoor Unit
3 Outdoor Unit
HP
38
40
42
Model Name
Combination Unit
ARUB380DTE4
ARUB400DTE4
ARUB420DTE4
Independ-
ent Unit
ARUB200DTE4
ARUB200DTE4
ARUB180DTE4
ARUB180DTE4
ARUB200DTE4
ARUB140DTE4
ARUB100DTE4
Refigerant charging
amount
kg
lbs
10.7 × 2
10.7 × 2
(10.7 × 2) + 7.7 × 1
Number of maxmum connectable indoor units
23.6 × 2
23.6 × 2
(23.6 ×2) + 16.9.0 × 1
Net Weight
kg
61(64)
64
64
lbs
285 × 2
285 × 2
285 × 1 + 245 x 1 + 208 × 1
Dimensions
(WxHxD)
mm
628 × 2
628 × 2
628 × 1 + 540 × 1 +459 × 1
inch
(1,240×1,680×760)×2 (1,240×1,680×760)×2
(1,240×1,680×760)×2
+ (920×1,680×760)×1
Pipe
Connc-
tions
Liquid Pipes mm(inch)
(48.8×66.1×29.9)×2
(48.8×66.1×29.9)×2
(48.8×66.1×29.9)×2
+(36.2×66.1×29.9)×1
Low Pressure Gas Pipes mm(inch)
19.05(3/4)
19.05(3/4)
19.05(3/4)
High Pressure Gas Pipes mm(inch)
41.3(1 5/8)
41.3(1 5/8)
41.3(1 5/8)
Unit
3 Outdoor Unit
HP
44
46
48
Model Name
Combination Unit
ARUB440DTE4
ARUB460DTE4
ARUB480DTE4
Independ-
ent Unit
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB140DTE4
ARUB160DTE4
ARUB180DTE4
ARUB100DTE4
ARUB100DTE4
ARUB100DTE4
Refigerant charging
amount
kg
lbs
(10.7 × 2) + 7.7 × 1
(10.7 × 2) + 7.7 × 1
(10.7 × 2) + 7.7 × 1
Number of maxmum connectable indoor units (23.6 ×2) + 16.9.0 × 1 (23.6 ×2) + 16.9.0 × 1 (23.6 ×2) + 16.9.0 × 1
Net Weight
kg
64
64
64
lbs
285 × 1 + 245 x 1 + 208 × 1 285 × 1 + 245 x 1 + 208 × 1
285 × 2 + 208 × 1
Dimensions
(WxHxD)
mm
628 × 1 + 540 × 1 +459 × 1 628 × 1 + 540 × 1 +459 × 1
628 × 2 + 459 × 1
inch
(1,240×1,680×760)×2
+ (920×1,680×760)×1
(1,240×1,680×760)×2
+ (920×1,680×760)×1
(1,240×1,680×760)×2
+ (920×1,680×760)×1
Pipe
Connc-
tions
Liquid Pipes mm(inch)
(48.8×66.1×29.9)×2
+(36.2×66.1×29.9)×1
(48.8×66.1×29.9)×2
+(36.2×66.1×29.9)×1
(48.8×66.1×29.9)×2
+(36.2×66.1×29.9)×1
Low Pressure Gas Pipes mm(inch)
19.05(3/4)
19.05(3/4)
19.05(3/4)
High Pressure Gas Pipes mm(inch)
41.3(1 5/8)
41.3(1 5/8)
41.3(1 5/8)
Unit
3 Outdoor Unit
HP
50
52
54
Model Name
Combination Unit
ARUB500DTE4
ARUB520DTE4
ARUB540DTE4
Independ-
ent Unit
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB200DTE4
ARUB100DTE4
ARUB120DTE4
ARUB140DTE4
Refigerant charging
amount
kg
lbs
(10.7 × 2) + 7.7 × 1
(10.7 × 2) + 7.7 × 1
10.7 × 3
Number of maxmum connectable indoor units (23.6 ×2) + 16.9.0 × 1 (23.6 ×2) + 16.9.0 × 1
23.6 × 3
Net Weight
kg
64
64
64
lbs
285 × 2 + 208 × 1
285 × 2 + 208 × 1
285 × 2 + 208 × 1
Dimensions
(WxHxD)
mm
628 × 2 + 459 × 1
628 × 2 + 459 × 1
628 × 2 + 540 × 1
inch
(1,240×1,680×760)×2
+ (920×1,680×760)×1
(1,240×1,680×760)×2
+ (920×1,680×760)×1
(1,240×1,680×760)×3
Pipe
Connc-
tions
Liquid Pipes mm(inch)
(48.8×66.1×29.9)×2
+(36.2×66.1×29.9)×1
(48.8×66.1×29.9)×2
+(36.2×66.1×29.9)×1
(48.8×66.1×29.9)×3
Low Pressure Gas Pipes mm(inch)
19.05(3/4)
19.05(3/4)
19.05(3/4)
High Pressure Gas Pipes mm(inch)
41.3(1 5/8)
41.3(1 5/8)
41.3(1 5/8)