Installation Manual  

17

Installation

ENGLISH

CAUTION :

The connecting cable connected to the indoor and outdoor unit should be complied with the fol-
lowing specifications (This equipment shall be provided with a cord set complying with the
national regulation).

If the supply cord is damaged, it must be replaced by a special cord or assembly available from
the manufacturer of its service agent.

u

Precautions when laying power and ground wiring

Use round pressure terminals for connections to the power terminal block.
When laying ground wiring, you must use round pressure terminals.

When none are available, follow the instructions below.

• Do not connect wiring of different thicknesses to the power terminal block. (Slack in the power wiring

may cause abnormal heat.)

• When connecting wiring which is the same thickness, do as shown in the figure below.

• For wiring, use the designated power wire and connect firmly, then secure to prevent outside pressure

being exerted on the terminal block.

• Use an appropriate screwdriver for tightening the terinal screws. A screwdriver with a small head will

strip the head and make proper tighterning impossible.

• Over-tightening the terminal screws may break them.

AWG18

20mm

35±5mm

GN/YL

10±3mm

Round pressure terminal

Power wire(Ground wire)

Содержание Multi V Art Cool ARNU123SFA4

Страница 1: ...he national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly INSTALLATION MANUAL AIR CONDITIONER P NO MFL67798127 Art Cool Gallery Series Original instruction http www lghvac com Copyright 2015 2018 LG Electronics Inc All Rights Reserved ENGLISH FRANÇAIS ESPAÑOL ...

Страница 2: ...to hold the unit s weight It may be necessary to construct a strong wood or metal frame to provide added support in a room Properly insulate any tubing run inside a room to prevent sweating that can cause dripping and water damage to wall and floors in moist or uneven locatinons Use a raised concrete pad or concrete blocks provide a solid level foundation for the outdoor unit This prevents water d...

Страница 3: ... drill o Horizontal meter o Flaring tool set o Specified torque wrenches different depending on model No o Spanner Half union o A glass of water o Screw driver o Hexagonal wrench o Gas leak detector o Vacuum pump o Gauge manifold Installation Parts 4 Safety Precautions 5 Installation 8 Selection the best location 8 Features 8 Preparing Work for Installation 9 Fixing Indoor Unit 10 Drill a Hole in ...

Страница 4: ...4 Indoor Unit Installation Parts Installation Parts Air Intake Air Outlet Type A screw and plastic anchor Installation guide map Installation Parts Read carefully and then follow step by step ...

Страница 5: ...d electrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the product There is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire or electric shock Always install a dedicated circuit and breaker Improper wiring or installation may cause fire or electric shock...

Страница 6: ...rty damage product failure and personal injury Use Inert nitrogen gas when doing leakage test Do not compress air or Oxygen and Do not use Flammable gases Otherwise it may cause fire or explosion There is the risk of death injury fire or explosion Operation Do not store or use flammable gas or combustibles near the product There is risk of fire or failure of product ...

Страница 7: ...or unit could damage the neighborhoods It may cause a problem for your neighbors Use two or more people to lift and transport the product Avoid personal injury Do not install the product where it will be exposed to sea wind salt spray directly It may cause corrosion on the product Corrosion particularly on the condenser and evaporator fins could cause product malfunction or inefficient operation D...

Страница 8: ...ere there are no obstacles in front of the unit Make sure that condensation drainage can be conveniently routed away Do not install near a doorway Ensure that the space around the left and right of the unit is more than 50cm The unit should be installed as high on the wall as possible allowing a minimum of 10cm from ceiling Use a stud finder to locate studs to prevent unnecessary damage to the wal...

Страница 9: ...ide cover of desired connecting direction then cover side is separated 3 Pick the pipe hole of the side cover CAUTION After removing the pipe hole cut the burr for safety When making pipe path through rear wall you don t need to pick the pipe hole Notice Drain hose junction 1 Remove the rubber cap in the desired drain direc tion 2 Insert drain hose into the handle of drain pan and join drain hose ...

Страница 10: ...ted horizon by horizontal meter on the horizontal setting line and fix lightly the map by adhesive tape 4 Drill the Pierced part as a diameter of 50mm 2 for connecting piping In case of piercing rear surface 6 First Drive the two points of the upper parts by screws Leave 10mm 0 5 for hanging the product 8 Secure the lower screws first and then completely tighten the upper screws 10 Once completed ...

Страница 11: ...emoving burrs put the end of the copper tube pipe in a downward direction while removing burrs location is also changed in order to avoid dropping burrs into the tubing Putting nut on Remove flare nuts attached to indoor and outdoor unit then put them on pipe tube having completed burr removal not possible to put them on after flaring work Flaring work 1 Firmly hold copper pipe in a die in the dim...

Страница 12: ...age furniture or floors Foamed polyethylene or equivalent is recommended 1 Route the indoor tubing and the drain hose in the direction of rear left or right 2 Tape the tubing drain hose and the connecting cable Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit Inclined Inside is shiny without scratches...

Страница 13: ...p the area which accommodates the rear piping housing section with vinyl tape 3 Bundle the piping and drain hose together by wrap ping them with vinyl tape over the range within which they fit into the rear piping housing section Wrap with vinyl tape Drain hose Pipe Vinyl tape wide Indoor unit tubing Flare nut Pipings Torque wrench Indoor unit tubing Spanner fixed Connection pipe Flare nut Vinyl t...

Страница 14: ...ain Piping 1 To check the drainage Pour a glass of water on the evaporator Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit 2 Drain piping The drain hose should point downward for easy drain flow Do not make drain piping Air Waving Water leakage Ditch Water leakage Downward slope Downward slope Downward slope Water leakage Tip of drai...

Страница 15: ...d fix the power cord in the bottom groove of cover side left 2 Assemble connecting lead wire with controller fix the upper part of panel front and match the lower part of panel front 3 Screw up panel front and suspend the hook of panel front in the groove Comm PCB Connector Panel Front Connector Comm PCB Connector ...

Страница 16: ...tice Be sure to connect wires according to the wiring diagram Connect the wires firmly so that not to be pulled out easily Connect the wires according to color codes by referring the wiring diagram CAUTION After the confirmation of the above conditions prepare the wiring as follows 1 Never fail to have an individual power circuit specifically for the air conditioner As for the method of wiring be ...

Страница 17: ...nd wiring you must use round pressure terminals When none are available follow the instructions below Do not connect wiring of different thicknesses to the power terminal block Slack in the power wiring may cause abnormal heat When connecting wiring which is the same thickness do as shown in the figure below For wiring use the designated power wire and connect firmly then secure to prevent outside...

Страница 18: ...Hz 7 1 Ø 100 V 50 60 Hz G 1 Ø 220 240 V 50 Hz 1 Ø 220 V 60 Hz Total Cooling Capacity in Btu h EX 5 000 Btu h 05 18 000 Btu h 18 Combination of Inverter Type and Cooling Only or Heat Pump N AC Inverter and H P V AC Inverter and C O U DC Inverter and H P and C O System with Indoor Unit using R410A LGETA U Ex URN Combinations of functions A Basic function L Neo Plasma Wall Mounted C Plasma Ceiling Ca...

Отзывы: