STD. WALL-MOUNTED | 59
Standard W
all-Mounted
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
MULTI
F
MAX
MULTI
F
General Data / Specifications
Model Name
LMN077HVT
LSN090HSV4
LSN120HSV4
LMN157HVT
LSN180HSV4
LMN247HVT
Nominal Cooling Capacity (Btu/h)
1
7,000
9,000
12,000
14,300
18,000
24,000
Nominal Heating Capacity (Btu/h)
1
8,100
10,400
13,800
16,500
20,800
27,000
Operating Range
Cooling (°F WB)
57-77
Heating (°F DB)
59-81
Fan
Type
Cross Flow
Motor Output (W) x Qty.
14.4 x 1
76.0 x 1
Motor/Drive
Brushless Digitally Controlled / Direct
Airflow Rate CFM (H/M/L)
198 / 177 / 162
247 / 230 / 212
335 / 318 / 300
371 / 318 / 247
572 / 501 / 434
720 / 600 / 466
Unit Data
Refrigerant Type
2
R410A
Refrigerant Control
EEV
Power Supply V, Ø, Hz
3
208-230, 1, 60
Rated Amps (A)
0.1
0.2
0.3
Sound Pressure Level ±3 dB(A)
(H/M/L)
4
33 / 30 / 26
33 / 30 / 27
39 / 36 / 31
43 / 39 / 34
37 / 33 / 28
42 / 39 / 36
Dimensions (W x H x D, in.)
35-1/4 x 11-3/8
x 8-9/32
34-7/8 x 11-1/4
x 8-1/4
34-7/8 x 11-1/4
x 8-1/4
35-1/4 x 11-3/8
x 8-9/32
40-9/16 x 12-13/16
x 9-13/16
40-9/16 x 12-25/32
x 9-27/32
Net Unit Weight (lbs.)
23
20
20
23
31
32
Shipping Weight (lbs.)
26
36
37
Power Wiring / Communications
Cable (No. x AWG)
5
4 x 18
Heat Exchanger (Row x Column x
Fin / inch) x Number
(2 x 16 x 23) x 1
(3 x 18 x 22) x 1
Pipe Size
Liquid (in.)
1/4
Vapor (in.)
3/8
1/2
Connection Size
Liquid (in.)
1/4
3/8
1/4
Vapor (in.)
3/8
5/8
1/2
Drain O.D. / I.D. (in.)
27/32, 5/8
Table 29: Multi F Standard Wall-Mounted Indoor Unit General Data.
STANDARD WALL-MOUNTED INDOOR UNITS
1
Nominal capacity is rated 0 ft. above sea level with corresponding refrigerant piping length in
accordance with standard length of each outdoor unit and a 0 ft. level difference between outdoor and
indoor units. All capacities are net with a combination ratio between 95 – 105%.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF
wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Nominal heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF
wet bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
2
This unit comes with a dry helium charge.
3
Acceptable operating voltage: 187V-253V.
4
Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the
same in both cooling and heating mode. These values can increase due to ambient conditions during
operation.
5
All power wiring / communications cable to be minimum 18 AWG, 4-conductor, stranded, shielded, and
must comply with applicable local and national codes.