INSTALLATION OF OUTDOOR UNIT
11
ENGLISH
Read completely, then follow step by step.
You need to select adequate installation location
considering the following conditions, and make
sure to acquire the consent of the user.
Select the best location
1
If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.
2
Ensure that the spaces indicated by arrows
around front, back and side of the unit.
3
Do not place animals and plants in the path of
the warm air.
4
Take the air conditioner weight into account
and select a place where noise and vibration
are minimum.
5
Select a place so that the warm air and noise
from the air conditioner do not disturb neigh-
bors.
6
Place that can sufficiently endure the weight
and vibration of the outdoor unit and where
even installation is possible.
7
Place that has no direct influence of snow or
rain.
8
Place with no danger of snowfall or icicle drop.
9
Place without weak floor or base such as
decrepit part of the building or with a lot of
snow accumulation.
10
Sufficient ventilation is secured.
If the outdoor unit is installed on a roof structure,
be sure to level the unit. Ensure the roof struc-
ture and anchoring method are adequate for the
unit location. Consult local codes regarding
rooftop mounting.
more than
70cm
more than
30cm
more than
30cm
more than
60cm
more than 60cm
more than
70cm
more than
30cm
more than 60cm
more than
30cm
more than
60cm
INSTALLATION OF OUTDOOR UNIT
Outdoor unit
Rooftop Installations
Содержание MU2R15
Страница 26: ...FUNCTION 26 14 16 1Ø kBtu h 1Ø kBtu h 27 30 18 21 24 1Ø kBtu h DIPSW1 5 DIPSW1 5 DIPSW1 5 ENGLISH ...
Страница 122: ...FONCTION 25 FRANÇAIS 14 16 1Ø kBtu h 40 1Ø kBtu h 27 30 1Ø kBtu h DIP SW 18 21 24 1Ø kBtu h SW01N DIP_SW01D 5 DIP_SW1 5 ...
Страница 154: ...FUNKTION 25 DEUTSCH 14 16 1Ø kBtu h 40 1Ø kBtu h 27 30 1Ø kBtu h DIP SW 18 21 24 1Ø kBtu h SW01N DIP_SW01D 5 DIP_SW1 5 ...
Страница 218: ...FUNKCE 25 ČEŠTINA 14 16 1Ø kBtu h 40 1Ø kBtu h 27 30 1Ø kBtu h DIP SW 18 21 24 1Ø kBtu h SW01N DIP_SW01D 5 DIP_SW1 5 ...
Страница 282: ...FUNKCJA 25 POLSKI 14 16 1Ø kBtu h 40 1Ø kBtu h 27 30 1Ø kBtu h DIP SW 18 21 24 1Ø kBtu h SW01N DIP_SW01D 5 DIP_SW1 5 ...
Страница 482: ......