9-2
CHECKING FLOW CHART BY FAIRURE
No Display (No Power)
Check AC input of SMPS PCB
- SMPS PCB CN1 (pin 1 and 3)
Control Dead
Select a function
Yes
Yes
Any beeping
Sound?
Normal?
120V AC?
Normal?
END
2
No
Yes
Yes
No
No
No
No
Replace the MAIN PCB
(EBR64624503)
Replace the DISPLAY
(EAJ61309901)
1
Normal?
Replace the SMPS PCB
(EBR64624701)
Replace the SMPS PCB
(EBR64624701)
Yes
END
END
END