4-4
Broil Element
Bake Element
Convection element
Vent motor
1. Refer to page 3-4 for disassembly
2. Measure the resistance after cool down
(Multiple meter scale : R x 1)
Components
Test procedures
Results
H
C
L
Normal: Approximately
Inner: 22.5
Ω
Outer: 36.9
Ω
Replace if: Infinite (opened)
1. Refer to page 3-8 for disassembly
2. Measure the resistance after cool down
(Multiple meter scale : R x 1)
Normal: Approximately 22.5
Ω
Replace if: Infinite (opened)
1. Refer to page 3-4 for disassembly
2. Measure the resistance after cool down
(Multiple meter scale : R x 1)
Normal: Approximately 32.5
Ω
Replace if: Infinite (opened)
1. Refer to page 3-6 for disassembly
2. Measure the resistance after cool down
(Multiple meter scale : R x 1)
Normal: Approximately
H ~ C: 16
Ω
L ~ C: 20
Ω
Replace if: Infinite (opened)
below 5
Ω
(shorted)
NOTE:
Ω
Value should be
tested at room temperature
(77F/25˚C)
NOTE:
Ω
Value should be
tested at room temperature
(77F/25˚C)
NOTE:
Ω
Value should be
tested at room temperature
(77F/25˚C)
NOTE:
Ω
Value should be
tested at room temperature
(77F/25˚C)
NOTE:
Outer Broil element
use Outer yellow and Blue
terminals to check resistance.
Inner Broil element use inner
yellow and pink terminals to
check resistance.