Troubleshooting
Problem
Checklist
Remedy List
1. Nothing works
Power supply to unit
Re-set circuit breaker or change fuse
PCB fuse
Change fuse
Interconnecting wiring
Look for break in cable or loose connection
PCB varistor
Replace PCB
Transformer Replace
PCB
2. Power on but system
Re-set control switch
Re-set
will not function
Handset control
Change batteries ( or hand set )
3. Power on but indoor
Mode on hand set
Change function
will not function
Power on fan terminal (pcb)
No power check relay, if faulty replace
Evaporator sensor
If short circuit, replace
Connector plug
Repair or replace
Motor overload
Wait to reset and check amps
Faulty motor
Replace
Evaporator frozen
Defrost and check filter / gas charge & de-ice sensor
Motor capacitor
Replace
4. Power on but compressor
Room temp set point
Adjust on hand set
will not function
Relay on PCB
Replace relay or PCB
Comp contactor
If power on contactor coil, replace contactor
Comp overload
Re set, check amps and set point
Indoor sensor(de-ice )
See control functions
Comp internal overload
Allow comp to cool down, check gas
Compressor terminals
Check for good connection
5. Power on but outdoor
De-ice sensor (heating)
Wait for defrost to terminate
fan will not function
Ambient temp low
Check gas pressure
Outdoor sensor
See control functions
Indoor coil too hot
Clean filter
Fan relay on PCB
Replace relay or PCB
Faulty motor
Replace motor
6. Power on but indoor
Connector plug
Replace or repair
manual key will not
Faulty switch
Replace switch or PCB
function
7. Power on but indoor
Connector plug
Replace or repair
display will not function
Faulty display
Replace display or PCB
Reset switch position
Correct or operate once
8. Indoor up-down louver
Handset control
Change function
will not function
Faulty stepping motor
Replace
Connector plug
Replace or repair
Содержание LV-C362FLA0