Connecting Cables between Indoor Unit and Outdoor Unit
- 28 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1) Connecting cables to the Indoor Unit
■
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit
respectively
The power cord connected to the outdoor unit should be
complied with the following specifications (Rubber
insulation, type H05RN-F approved by HAR or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly availible from the manufacturer of its service agent.
The connecting cable connected to the indoor and outdoor
unit should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR or SAA).
CAUTION
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2
(36K/42K)
1.25mm
2
(48K/60K)
20mm
GN/YL
Capacity
36K BTU/h
42K BTU/h
48K BTU/h
60K BTU/h
1 Phase
5.5mm
2
8.5mm
2
8.5mm
2
8.5mm
2
3 Phase
-
-
3.5mm
2
5.5mm
2
NORMAL CROSS-SECTIONAL AREA
• Cooling only type
Terminals on the indoor unit
1(N) 2(L) 3
4
5
1(N) 2(L) 3
4
5
Terminals on the outdoor unit
POWER INPUT
(1Ø, 220V)
1(L)
R
S
T
N
2(N)
POWER INPUT
(3Ø, 220V)
■
36K/42K/48K/60K Btu (1Ø, 220V)
• Cooling only type
Terminals on the indoor unit
3
3
2
2
1
1
Terminals on the outdoor unit
■
48K/60K Btu (3Ø, 220V)
Содержание LV-C362FLA0