-29-
(TROUBLE 6) When toaster operates, strange code can be seen on the display and stop with beep sound.
1. “F-1” code.
No continuity.
Continuity.
Defective
thermistor
Replace thermistor
Check continuity
of thermistor.
Check the
continuity of
heater.
Check the
connection
between CN3
connector and
PCB assembly.
Continuity.
No continuity.
Continuity.
No continuity.
Defective heater
Defective PCB
assembly.
2. “F-2” code.
Attached
Seperated
2 wire leads are
shorted contact
Internal
temperature is
over 220 deg c
Apart 2 wire leads
as far as possible.
Check the CN3
connector
whether 2 wire
leads are
attached.
3. “HOT” code.
Allow the toaster to
cool down.
(Automatically fan
will blow for
3 minutes to cool
this unit)
Defective PCB
assembly.
Replace PCB
assembly.
Replace toaster
Assembly.
Replace PCB
Assembly.
Loose connection
Connect them
tightly.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Содержание LTRM1240SB
Страница 8: ... 7 B MATRIX CIRCUIT FOR TOUCH KEY BOARD ...
Страница 31: ... 30 EXPLODED VIEW INTRODUCTION ...
Страница 34: ... 33 LATCH BOARD PARTS WSZ085 56912B 55262A 466003 466001 466001 43500A 44510A ...
Страница 36: ... 35 BASE PLATE PARTS 63302A WTT021 65006A 647781 WTT028 WTT021 WSZ002 56170D 63303A ...
Страница 37: ... 36 SENSOR PARTS WTP004 56501A WTT021 54974T ...