-26-
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective
thermostat.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
(TROUBLE 2) Microwave oven does not operate at all, Display window does not display any figures,
and no input is accepted.
1. Fuse blows.
Continuity.
No continuity.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor,
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of monitor
switch (with
door closed).
Continuity.
No continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor,
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of primary
switch (with
door opened)
Normal.
Replace fuse
Fuse blows again
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Содержание LTRM1240SB
Страница 8: ... 7 B MATRIX CIRCUIT FOR TOUCH KEY BOARD ...
Страница 31: ... 30 EXPLODED VIEW INTRODUCTION ...
Страница 34: ... 33 LATCH BOARD PARTS WSZ085 56912B 55262A 466003 466001 466001 43500A 44510A ...
Страница 36: ... 35 BASE PLATE PARTS 63302A WTT021 65006A 647781 WTT028 WTT021 WSZ002 56170D 63303A ...
Страница 37: ... 36 SENSOR PARTS WTP004 56501A WTT021 54974T ...
Страница 39: ......