5-3
CONVERSION TO LP GAS
WARNING
• Turn off the electrical supply and
gas supply going to the range.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.
BURNER OUTPUT RATINGS; BTU/HR
BTU RATE
ORIFICE CODE
LSRG309ST
LSRG309ST
LF
LR
RR
RF
INNER
OUTER
CTR
BROIL
BAKE
12,000
9,100
5,000
19,000
8,000
15,500
18,000
C
D
G
B
A
I
A
B
Natural Gas, 5” W.C.P
BURNER
MODEL
Orifice Locations for Natural Gas
D
I
A
C
G
B
4) To prevent leakage, make sure the orifice
spuds are securely screwed into the gas
supply tubes.
5) For the extra burner (right front) of
LSRG309ST, three orifice spuds will be
needed.
6) Put the old orifice spuds into conversion kits
and place back on the range for possible
future conversion.
NOTE: If an orifice spud is accidentally
dropped, the cooktop plate can be
raised (see the page 3-4)