Installation
6RMI0-02A
63
Inverter Single
Inverter Single
Inverter Single
Inverter Single
Fixing Installation Plate
The wall you select should be strong and solid enough to
prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete wall,
use anchor bolts.
• Mount the installation plate horizontally by aligning the
centerline using Horizontal meter .
2. Measure the wall and mark the centerline. It is also important to use caution concerning the location of the
installation plate. Routing of the wiring to power outlets is through the walls typically. Drilling the hole through
the wall for piping connections must be done safely.
Installation Plate
Chassis
Hook
Type "A" Screws
Ø70(2.76)
133(5.2)
95(3.7)
Right rear piping
Left rear piping
Installation Plate
Place a level on raised tab
Unit Outline
217(8.5)
175(6.9)
[Unit : mm(inch)]
442(17.4)
442(17.4)
Ø70(2.76)
70(2.76)
Ø70(2.76)
• Drill the piping hole with a ø70mm(2.76in) hole core
drill. Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
Drill a Hole in the Wall
5-7mm
(3/16in~5/16in)
Indoor
WALL
Outdoor