Installation
6RMI0-02A
69
Inverter Single
Inverter Single
Inverter Single
Inverter Single
Wrap the insulation material around the connecting
portion.
1. Overlap the connection pipe insulation material and
the indoor unit pipe insulation material. Bind them
together with vinyl tape so that there may be no gap.
2. Set the tubing cudtting line upward.
Wrap the area which accommodates the rear piping
housing section with vinyl tape.
3. Bundle the piping and drain hose together by
wrapping them with vinyl tape sufficient enough to
cover where they fit into the rear piping housing
section.
Finishing the indoor unit installation
1. Mount the tubing holder in the original positon.
2. Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
3. Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots (clicking sound).
4. Finish the assembly by screwing the unit to the
installation plate by using two pieces of type "C"
screws. And assemble a chassis cover.
Installation of filters
1. Pull out the triple filter and allergy free filter from the
separately packed plastic bag.
2. Insert the triple filter into the left case and insert the
allergy free filter into the right case.
3. Detach two attached tapes from the plasma filter.
Insulation material
Vinyl tape(narrow)
Connection pipe
Connecting cable
Vinyl tape (wide)
Wrap with vinyl tape
Indoor unit pipe
Pipe
Gas Pipe
Liquid Pipe
Cutting Line
Cutting Line
Good Case
Bad Case
* Tubing cutting line have to be upward.
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
Type 'C' screw
Triple Filter
Plasma Filter
Allergy Free Filter