–14–
2) Preparation of installation parts and tools
No.
Installation Parts, Tools
Use
1
Pipe cutter (MAX 35mm Copper pipe)
Cutting the pipings
2
Remear
Remove burrs from cut edges of pipes.
3
Wrench (H5, H4 hexagonal wrench)
To open the service valve
4
Pipe bender
Bending the pipings
5
Leak detector
Check a gas-leakage of connecting part
of the pipings
6
Manifold gauge
To measure the pressure, to charge the refrigerant
7
Charge-nipple
To connect the bombe
8
Vacuum pump
To remove the air in the pipe.
9
Charge cylinder balance
To measure the refrigerant amount
10
Bombe (Freon-22)
Gas charge
Air purge
Cleaning the pipe
11
Spanner
To tighten the connecting parts of the pipings
12
Monkey spanner
13
Driver( , )
14
Benchi (150mm)
Cutting the wires
15
Tapeline
To measure the length
16
Core drill
To make holes through the concrete wall and blocks
17
Voltmeter, Amperemeter, Clampmeter
To measure the current and voltage
18
Insulation resistance tester
To measure the insulation resistance
19
Glass thermometer
To measure the intake and outlet air temperature of the indoor unit
20
Copper tubes
To use the connecting pipings
21
Insulation material
To cover the connecting pipings
22
Tape
To finish the connecting pipings
23
Electrical Leakage Breaker
To shut off the main power
24
Cable
To connect the cable from outdoor unit to indoor unit
27
Drain hose sockets, elbows
To remote the condensing water
Содержание LP-8091PC
Страница 1: ...Package Air Conditioner SERVICE MANUAL MODEL LP 8091PC Библиотека СОК ...
Страница 42: ...9 Electronic Control Device 42 9 1 MAIN P C B ASSY ...
Страница 44: ...10 Schematic Diagram 44 Circuit and Troubleshooting ...
Страница 46: ... 46 14 17 10 19 29 1 13 11 8 1 15 12 8 9 20 22 5 6 7 2 4 3 2 1 16 ...
Страница 49: ... 49 Outdoor Unit 4 1 4 2 4 4 4 3 12 8 ...
Страница 52: ...P No 3828A30074W April 2000 Printed in Korea ...