5-15
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective P.C.B
assembly
Replace P.C.B
assembly
Disconnect the
wire leads from
relay 2 and
check continuity
of relay2.
(Operate the unit)
Abnormal
Normal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Check high vol-
tage transformer
Normal
Normal
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Check high vol-
tage diode
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check high vol-
tage capacitor
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run
(Display operates properly)
Output is full power
when you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective P.C.B.
assembly.
Replace P.C.B.
assembly.
NOTE : • Make sure the wire leads correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Содержание LMAB1240ST
Страница 28: ...DOOR PARTS 6 2 13552A 13213A 13352A 13581A 14970A 14026A 15006A 13536A 13551A EV ...
Страница 29: ...CONTROL PANEL PARTS 6 3 24781M 23551A 23550D 24510L 24970A 23551B 268711 WTP018 24930D EV ...
Страница 30: ...OVEN CAVITY PARTS 6 4 36549S 33052A WTP013 33390G WTT010 WSZ185 33112U 35889A EV ...
Страница 31: ...LARCH BOARD PARTS 6 5 WSZ085 466001 466003 466001 43500A EV ...
Страница 34: ...BASE PLATE PARTS 6 8 56170D 63302A 63303A WTT021 WSZ002 WTT028 647781 948502 EV ...
Страница 35: ......