5-13
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
Continuity.
Malfunction of
secondary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
No continuity.
Check continuity
of secondary
switch (with
door opened).
(TROUBLE 2) Oven does not operate at all, Display window does not display any figures,
and no input is accepted.
NOTE : All these switches must be replaced at the same time. Refer to page 5-7, 5-8
2. Fuse does not
blow.
No continuity.
No continuity.
Replace power
supply cord.
Defective
thermostat.
Defective power
supply cord.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
Continuity.
Содержание LMAB1240ST
Страница 28: ...DOOR PARTS 6 2 13552A 13213A 13352A 13581A 14970A 14026A 15006A 13536A 13551A EV ...
Страница 29: ...CONTROL PANEL PARTS 6 3 24781M 23551A 23550D 24510L 24970A 23551B 268711 WTP018 24930D EV ...
Страница 30: ...OVEN CAVITY PARTS 6 4 36549S 33052A WTP013 33390G WTT010 WSZ185 33112U 35889A EV ...
Страница 31: ...LARCH BOARD PARTS 6 5 WSZ085 466001 466003 466001 43500A EV ...
Страница 34: ...BASE PLATE PARTS 6 8 56170D 63302A 63303A WTT021 WSZ002 WTT028 647781 948502 EV ...
Страница 35: ......