(7) Test running
Battery Cover
Discharge air
Bolt
Tubing connection
Settlement of Outdoor Unit
• Anchor the outdoor unit with a bolt and nut
(ø10cm) tightly and horizontally on a concrete or
rigid mount.
• When installing on the wall, roof or rooftop,
anchor the mounting base securely with a nail or
wire assuming the influence of wind and earth-
quake.
• In the case when the vibration of the unit is con-
veyed to the house, settle the unit with an anti-
vibration rubber.
2) Evaluation of the performance
1. Measure the temperature of the intake and
discharge air.
2. Ensure the difference between the intake
temperature and the discharge one is more
than 8°C.
1) Connection of power supply
1. Connect the power supply cord to the inde-
pendent power supply.
2. Prepare the remote control.
• Insert two batteries provided.
Remove the battery cover from the remote con-
troller.
• Slide the cover according to the arrow direction.
Insert the two batteries.
(Two "R03" or "AAA" dry-cell batteries or equiv-
alent.)
• Be sure that the (+) and (-) directions are cor-
rect.
• Be sure that both batteries are new.
Re-attach the cover.
• Slide it back into position.
3. Operate the unit at cooling operation mode
for fifteen minutes or more.
Содержание LM-2561C3L
Страница 1: ...Multi Type Room Air Conditioner SERVICE MANUAL MODEL LM 2561C3L LM 2860C5L LM 3060H4L M LM 4260H3L M ...
Страница 12: ... 12 LM 4260H3L M 900 1 225 370 ...
Страница 57: ... 57 Electronic Control Device 1 Indoor MAIN P C B ASM ...
Страница 58: ... 58 2 Outdoor MAIN P C B ASM LM 2561C3L LM 4260H3L M ...
Страница 59: ... 59 MAIN P C B ASM LM 2860C5L LM 3060H4L M ...
Страница 60: ... 60 3 Display Ass y ...
Страница 61: ... 61 Schematic Diagram 1 Indoor LM 2561C3L LM 2860C5L LM 3060H4L M LM 4260H3L M ...
Страница 62: ... 62 2 Outdoor LM 2561C3L LM 4260H3L M ...
Страница 63: ... 63 LM 2860C5L LM 3060H4L M ...
Страница 82: ...P No 3828A20023R January 2001 Printed in Korea ...