Taping
Drain hose
Pipings
Connecting
cable
Plastic band
• Trap is required to prevent water from
entering into electrical parts.
Power cord
- 37 -
Seal a small opening
around the pipings
with gum type sealer.
Trap
Trap
3) Form the pipings
1. Wrap the connecting portion of indoor unit
with the Insulation material and secure it with
two Plastic Bands(for the left pipings).
• If you want to connect an additional drain hose,
the end of the drain-outlet should keep distance
from the ground.(Do not dip it into water, and fix
it on the wall to avoid swinging in the wind.)
2. Tape the Pipings, drain hose and Connecting
Cable from down to up.
3. Form the pipings gathered by taping along the
exterior wall and fix it onto the wall by saddle
or equivalent.
1. Tape the Pipings and Connectiong cable from
down to up.
2. Form the pipings gathered by taping along the
exterior wall and the Trap to be required to
prevent the room from entering the water.
3. Fix the pipings onto the wall by saddle or
equivalent.
In case of the Outdoor unit is installed bellow
position of the Indoor unit.
In case of the Outdoor unit is installed upper
position of the Indoor unit.
Содержание LM-2561C3L
Страница 1: ...Multi Type Room Air Conditioner SERVICE MANUAL MODEL LM 2561C3L LM 2860C5L LM 3060H4L M LM 4260H3L M ...
Страница 12: ... 12 LM 4260H3L M 900 1 225 370 ...
Страница 57: ... 57 Electronic Control Device 1 Indoor MAIN P C B ASM ...
Страница 58: ... 58 2 Outdoor MAIN P C B ASM LM 2561C3L LM 4260H3L M ...
Страница 59: ... 59 MAIN P C B ASM LM 2860C5L LM 3060H4L M ...
Страница 60: ... 60 3 Display Ass y ...
Страница 61: ... 61 Schematic Diagram 1 Indoor LM 2561C3L LM 2860C5L LM 3060H4L M LM 4260H3L M ...
Страница 62: ... 62 2 Outdoor LM 2561C3L LM 4260H3L M ...
Страница 63: ... 63 LM 2860C5L LM 3060H4L M ...
Страница 82: ...P No 3828A20023R January 2001 Printed in Korea ...