- 31 -
Connecting
cable
Drain hose
Indoor unit tubing
Flare nut
Pipings
Spanner
Torque wrench
Plastic bands
Insulation material
Press the lower left and right side of the unit
against the Installation Plate until the hooks
engage with their slots (sound click).
6. Indoor unit installation.
• Hook the indoor unit onto the upper position of
the installation plate. (Engage the two hooks of
the rear top of the indoor unit with the upper
edge of the installation plate.)
Ensure the hooks are properly seated on the
installation plate by moving it in left and right.
7. Connecting the pipings to the indoor unit.
• Align the center of the pipings and sufficiently
tighten the flare nut with fingers.
• Finally, tighten the flare nut with torque wrench
until the wrench clicks.
Wrench tightening the flare nut with forque
wrench, ensure the direction for tightening fol-
lows the arrows on the wrench.
8. Wrap the insulation material around the con-
necting portion.
CAUTION: Take care to arrange the pipings,
drain hose and cables as the right
upper picture for inserting it into the
indoor unit and refixing the tubing
holder easily.
Pipe Size
Torque
Liquid Side (1/4")
1.8kg m
Gas Side (3/8")
4.2kg m
Gas Side (1/2")
5.5kg m
Wrap the insulation material around the connecting
portion.
Содержание LM-2561C3L
Страница 1: ...Multi Type Room Air Conditioner SERVICE MANUAL MODEL LM 2561C3L LM 2860C5L LM 3060H4L M LM 4260H3L M ...
Страница 12: ... 12 LM 4260H3L M 900 1 225 370 ...
Страница 57: ... 57 Electronic Control Device 1 Indoor MAIN P C B ASM ...
Страница 58: ... 58 2 Outdoor MAIN P C B ASM LM 2561C3L LM 4260H3L M ...
Страница 59: ... 59 MAIN P C B ASM LM 2860C5L LM 3060H4L M ...
Страница 60: ... 60 3 Display Ass y ...
Страница 61: ... 61 Schematic Diagram 1 Indoor LM 2561C3L LM 2860C5L LM 3060H4L M LM 4260H3L M ...
Страница 62: ... 62 2 Outdoor LM 2561C3L LM 4260H3L M ...
Страница 63: ... 63 LM 2860C5L LM 3060H4L M ...
Страница 82: ...P No 3828A20023R January 2001 Printed in Korea ...