- 20 -
9. Set the pipings and the connecting cable to
the back of the chassis with the tubing
holder.
• Hook the edge of tubing holder to tap on chas-
sis and push the bottom of tubing holder to be
engaged in the bottom of chassis.
10. Indoor unit installation
• Hook the indoor unit onto the upper portion of
installation plate. (Engage the two hooks of the
rear top of the indoor unit with the upper edge
of the installation plate.)
Ensure the hooks are properly seated on the
installation plate by moving it in left and right.
Drain hose
Tubing holder
Taping
Piping
Push
2
Hook
1
Connecting
cable
Drain hose
Press the lower left and right side of the unit
against the Installation Plate until the hooks
engages with their slots (sound click).