- 19 -
Connecting
cable
Drain hose
Indoor unit tubing
Flare nut
Pipings
Spanner
Torque wrench
Plastic bands
Insulation material
Press the lower left and right side of the unit
against the Installation Plate until the hooks
engage with their slots (sound click).
6. Indoor unit installation.
• Hook the indoor unit onto the upper position of
the installation plate. (Engage the two hooks of
the rear top of the indoor unit with the upper
edge of the installation plate.)
Ensure the hooks are properly seated on the
installation plate by moving it in left and right.
7. Connecting the pipings to the indoor unit.
• Align the center of the pipings and sufficiently
tighten the flare nut with fingers.
• Finally, tighten the flare nut with torque wrench
until the wrench clicks.
Wrench tightening the flare nut with forque
wrench, ensure the direction for tightening fol-
lows the arrows on the wrench.
8. Wrap the insulation material around the con-
necting portion.
CAUTION: Take care to arrange the pipings,
drain hose and cables as the right
upper picture for inserting it into the
indoor unit and refixing the tubing
holder easily.
Pipe Size
Torque
Liquid Side (1/4")
1.8kg
·
m
Gas Side (3/8")
4.2kg
·
m
Gas Side (1/2")
5.5kg
·
m
Wrap the insulation material around the connecting
portion.
Содержание LM-2320C2L/M
Страница 1: ...Multi Type Room Air Conditioner SERVICE MANUAL MODEL LM 2320C2L M ...
Страница 44: ... 44 Electronic Control Device 1 Indoor Unit MAIN P C B ASSY 2 Display Ass y ...
Страница 45: ... 45 1 Indoor Unit Schematic Diagram ...
Страница 48: ... 48 B UNIT 9K 10 24 25 23 28 27 21 19 22 7 6 18 4 5 1 2 3 20 9 31 8 15 12 11 16 13 26 14 17 29 30 ...
Страница 52: ...P No 3828A30074X May 2000 Printed in Korea ...