Thermal Error
Condition.
The resistance of thermistor
not normally out put.
Is displayed?
Yes
Reconnect or
repair the
connector.
Is the connector
connected to heater
assembly disconnected or
disassembled?
Yes
No
Replace the
thermistor.
Is the thermistor operated
properly?
(range is 12~13k
Ω
)
No
Reconnect or
repair the
connector.
Is the connector
connected to main PCB
assembly disconnected or
disassembled? (RD6 : Thermistor)
No
Yes
Replace the
main PCB
assembly.
Is the resistor between
connectors out of range?
(RD6 pin2 ~ pin3)
- After remove the
connector from the PCB,
check the resistor.
(range is 12~13k
Ω
)
Yes
No
39
Содержание LD1454WBFES2
Страница 2: ......
Страница 19: ...5 WIRING DIAGRAM 19 ...
Страница 20: ...20 ...
Страница 51: ...10 EXPLODED VIEW A001 A020 A010 A050 A040 F001 51 E006 G009 E200 ACCESSORIES Hardness Strip Noise Strip ...
Страница 52: ...10 EXPLODED VIEW A001 A020 A010 A050 A040 F001 51 E006 G009 ACCESSORIES Hardness Strip ...
Страница 62: ...A157 A147 A144 A146 A142 A140 A070 A060 A156 A080 A150 A090 A155 A101 A102 A103 A110 61 ...
Страница 63: ...P No MFL63726506 ...