![LG LD1454WBFES2 Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/lg/ld1454wbfes2/ld1454wbfes2_service-manual_1896374034.webp)
Inlet Error
Is displayed?
Yes
Is the water tap opened?
No
Open the water tap.
Yes
Is the inlet hose kinked?
No
Repair the inlet hose.
Yes
Is the filter of inlet valve
clogged by impure water?
Yes
a) Close the water tap.
b) Unscrew the inlet hose.
(Inlet valve side)
c) Clean the filter of inlet valve.
No
Is the water pressure
very low? (below 0.5kgf/
㎠
)
Yes
No
Does the water supplied?
How to check the water supply
①
press 3 buttons at the same time.
(Half load, Delay start and Power)
②
press ‘Delay start’ button 3 times
Is the connector connected to
main PCB assembly disconnected
or disassembled? (NA8 : Flow meter)
No
Yes
Reconnect or
repair the connector.
Is the voltage between connectors
out of range? (NA8 pin1 ~ pin2)
- After remove terminal position
assurance (TPA) of connector,
check the voltage when water is
injected.
(The voltage is 2.5V AC (
±
15%)
Is the resistance vales between
connectors out of range?
(range is over 5M
Ω
)
(White 8P, Pin1~Pin2)
No
Replace the main
PCB assembly
Yes
The water is supplied.
Frequency is not increased
The water is not supplied.
Condition.
Not reached to the normal water level in spite of 10
min. water supply.
Reconnect or
repair the connector.
Is the connector connected
to main PCB assembly
disconnected or
disassembled? (NA4 : Aqua stop)
Yes
No
Install the pressure pump.
8.TROUBLE SHOOTING METHODS
34
Содержание LD1454WBFES2
Страница 2: ......
Страница 19: ...5 WIRING DIAGRAM 19 ...
Страница 20: ...20 ...
Страница 51: ...10 EXPLODED VIEW A001 A020 A010 A050 A040 F001 51 E006 G009 E200 ACCESSORIES Hardness Strip Noise Strip ...
Страница 52: ...10 EXPLODED VIEW A001 A020 A010 A050 A040 F001 51 E006 G009 ACCESSORIES Hardness Strip ...
Страница 62: ...A157 A147 A144 A146 A142 A140 A070 A060 A156 A080 A150 A090 A155 A101 A102 A103 A110 61 ...
Страница 63: ...P No MFL63726506 ...