Drain Error
Is displayed?
Yes
Does the drain motor operate?
How to check the water supply
①
press 3 buttons at the same time.
(Half load, Delay start and Power)
②
press ‘Delay start’ button 2 times
Motor rpm is not increased.
Motor rpm is increased.
Is the filter clogged?
Clean the filter
No
Is the connector connected to
main PCB assembly disconnected
or disassembled? (YL3 : Pump signal)
No
Yes
Reconnect or
repair the connector.
Is the connector connected to
drain motor disconnected
or disassembled?
Reconnect or
repair the connector.
Is the voltage between connectors
out of range?(YL3 pin1~pin2~pin3)
- After remove terminal position
assurance (TPA) of connector,
check the voltage when water is
drained.(The voltage is over 5V AC)
No
Replace the main
PCB assembly.
Yes
Is the outer drain hose
kinked or blocked or frozen?
Remove the cause of kink
or block.
No
Is the inner drain hose
and drain case
kinked or blocked or frozen?
Remove the cause of kink
or block.
Is the resistance values between
connectors out of range?
(range is 4~5
Ω
)
(Yellow 3P, pin1~pin2~pin3)
Yes
No
Replace the drain
motor
Yes
Yes
Yes
Yes
Condition.
Not fully drained out in
spite of 5 min. drain
operati
on.
36
Содержание LD1454WBFES2
Страница 2: ......
Страница 19: ...5 WIRING DIAGRAM 19 ...
Страница 20: ...20 ...
Страница 51: ...10 EXPLODED VIEW A001 A020 A010 A050 A040 F001 51 E006 G009 E200 ACCESSORIES Hardness Strip Noise Strip ...
Страница 52: ...10 EXPLODED VIEW A001 A020 A010 A050 A040 F001 51 E006 G009 ACCESSORIES Hardness Strip ...
Страница 62: ...A157 A147 A144 A146 A142 A140 A070 A060 A156 A080 A150 A090 A155 A101 A102 A103 A110 61 ...
Страница 63: ...P No MFL63726506 ...