Installation of IR Remote Sensor
15
1. Connect the IR sensor cable
to the CN-DISPLAY connector
of main PCB Assy.
2. Fix the rear side of the installation board with
the screw.
3. Now attach the IR PCB Assy at the rear
side of installation board.
When disassemble the IR remote sensor
from the installation board, use the driver as
shown in the right picture and insert it into the
hole with the arrow. And when you pull the driver
in the front direction, the IR remote sensor
will be separated.
The IR sensor cable is connected as factory default.
Fixate the IR Remote
Sensor cable to
the guide slot.
Use the screws
for fixate the unit
firmly on the wall.
Installation board
<Front side of
installation board>
<Rear side of
installation board>
Bottom
Wall
Side
Wall
Side
Wall
Side
Wall
Side
Wall
Side
Do not install the cable to be 10m or above.
(It can cause communication error.)
• When installing the extension cable, check the connecting direction of the connector of the IR remote sensor side
and the product side for correct installation.
• If you install the extension cable in the opposite direction, the connector will not be connected.
• Specification of extension cable: AWG 26 (2sim 7shield) or above