Fan speed is on low.
Fan speed is on medium.
Fan speed is on high.
CHAOS Air
Air circulation mode
Circulates the room air without cooling or heating.
1. Press the Start/Stop button. the unit will respond with a beep.
2. Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control.
Now each time that you press the Indoor Fan Speed Selector button, the fan speed is shifted from low to
CHAOS and back to low again.
(Function not Available)
39
Forced operation
Press the ON/OFF button on IR PCB
Assembly for 3 seconds, once you listen
beep sound remove your hand.
Note :1)
Forced operation button location
varies with model.
Use for ON/OFF the unit in case
of remote misplace.
LG
COMP
POWER
FILTER
TIMER
ON/OFF
Error Diagnosis
Sr.
No.
ERROR CODE
DIAGNOSIS
1
2
3
4
5
CH-01
CH-02
CH-05
CH-04
Check room thermistor
Check pipe thermistor (CN-Pipe/In)
Check Option PCB (EPROM)
Check float sensor / Jumper
DESCRIPTION
Recover after 5 seconds of operation when respective
thermistor healthy
Recover after 3 seconds of operation when respective
thermistor healthy
Check Interconnection of Option PCB and Power Reset
Recover after 4 minutes of operation when float sensor /
Jumper healthy
CH-09
Check Dipswitch setting and Power Reset
Check Dipswitch comm (Yes/No)