5-1-8. Operation in response to ambient temperature
The storage senses the ambient temperature and adjusts the temperature in the compartments accordingly. This keeps the
storage from being too cold or too warm because of seasonal variations and maintains exact temperatures in the
compartments.
5-1-9. Sequential operation of components
Components (compressor, 3-way valve and left/right seasoning heater) are operated in a specific order to prevent damage
and noise caused by simultaneous operation of all parts when the unit is started and after completing the self-test routine.
g
Operation order may slightly vary depending on temperature setting.
MICOM function and circuit description
- 13 -
Storage temperature
of the left and right
compartments
Operation in response to the ambient temperature
In general operation
Season
Spring
Summer
Autumn
Winter
Operation status
Operating order
Remarks
Initial
power-up
Temperature of
the left of right
sensor is >45°C
Temperature of
the left of right
sensor is <45°C
When returning to
normal status in test
mode
The 3-way valve is
opened to both
compartments for 3
minutes; then it is
opened to either
the left or the right
compartment,
depending on the
temperature in the
compartments.
Power
on
Power
on
All
loads
off
Compressor
on
Left
seasoning
heater
on
Right
seasoning
heater
on
3-way
valve
open
3-way
valve
left open
3-way
valve
open
3-way
valve
left open
Left
seasoning
heater
off
Right
seasoning
heater
off
Compressor
on
3-way
valve
open
3-way
valve
left
open
Compre
ssor on
Immediately
3 min
10 sec
Immediately 0.5 sec
5 sec
0.5 sec
3 sec
3 min
10 sec
7 min
3 sec
3 min