Input power of Environmental controlled anti-condensation
heater / Defrost period
GR-B24FWAHL / GR-B24FWSHL
Mullion heater
Relative
Humidity
Running rate in percentage(R) at
the ambient temperature(i)(%)
Input power at the ambient
temperature
16°C
22°C
32°C
16°C
22°C
32°C
0-10%
0.00
0.00
0.03
1.765
1.765
2.941
10-20%
0.06
0.06
0.33
1.765
1.765
2.941
20-30%
0.60
1.62
2.35
1.765
1.765
2.941
30-40%
2.76
9.24
2.56
1.765
1.765
2.941
40-50%
6.93
12.72
3.57
1.765
1.765
2.941
50-60%
8.01
11.70
1.11
3.941
3.941
5.411
60-70%
5.55
11.40
0.05
3.941
3.941
5.411
70-80%
3.30
7.92
0.00
3.941
3.941
5.411
80-90%
1.80
3.48
0.00
5.882
5.882
5.882
90-100%
0.99
1.86
0.00
5.882
5.882
5.882
GR-B24FWVFC
Mullion heater
Relative
Humidity
Running rate in percentage(R) at
the ambient temperature(i)(%)
Input power at the ambient
temperature
16°C
22°C
32°C
16°C
22°C
32°C
0-10%
0.00
0.00
0.03
0.000
0.000
0.000
10-20%
0.06
0.06
0.33
0.000
0.000
0.000
20-30%
0.60
1.62
2.35
0.000
0.000
0.000
30-40%
2.76
9.24
2.56
0.000
0.000
1.513
40-50%
6.93
12.72
3.57
0.000
0.000
2.017
50-60%
8.01
11.70
1.11
0.756
1.513
3.025
60-70%
5.55
11.40
0.05
1.513
2.017
4.033
70-80%
3.30
7.92
0.00
2.017
2.269
4.538
80-90%
1.80
3.48
0.00
3.025
5.042
5.042
90-100%
0.99
1.86
0.00
3.529
5.042
5.042
Environmental controlled anti-condensation heater
Anti-condensation heaters are turned on and off according to the control logic,
which is affected by ambient temperature and humidity condition in a normal
temperature setting. (Freezer compartment -18°C, Refrigerator compartment 4°C),
The input power of environmental controlled anti-condensation heater is given in
below table.