8) SELF-TEST
(1) Function to make service easy in case of occuring a trouble in the product.
(2) When occurring a trouble, if the button is pushed, but the function could not operate.
(3) If a toruble release during the representation of trouble, a refrigerator performs the normal function(RESET).
(4) To represent a ERROR CODE, it use FREEZE TEMP LEDs on TOP COVER. If ERROR occurs, the other LEDs except
ERROR CODE LEDs are all off.
ERROR CODE LEDs
OPERATION IN TROUBLE'S OCCURRING
NO.
ITEMS
F1 F2 F3 F4
DESCRIPTION
COMP
FAN
DEFROST HEATER
1
FREEZER
FREEZER SENSOR open
SENSOR abnormal
or short.
O
O
2
DEFROST
DEFROST SENSOR open
SENSOR abnormal
or short.
O
O
No defrosting
3
DEFROSTING
DEFROST HEATER,
FUNCTION
TEMP. FUSE open or
is abnormal
disconnection (Displayed
after at least 4 hours
O
O
O
from the trouble's
occurring.)
4
RT-SENSOR NOTE
1)
Room Temperature
abnormal
SENSOR open or short
O
O
O
- 20 -
VACATION
FREEZE TEMP
QUICK FREEZE
F1
ERROR CODE LEDs
F2
F3
F4
15 minutes On/
15 minutes Off
* NOTE 1) If one second pass after pressing the QUICK FREEZE and FREEZE TEMP buttons togather in normal operation,
operates as follow.
If normal, LEDs on the TOP COVER is all on.
If abnormal, LEDs are all on except VACATION LED.
RT-SENSOR
:ON
O : OPERATE NORMAL
:OFF
Содержание GR-359
Страница 3: ... 17 ASSEMBLY JAWS BOLT TOOL TUBE LOKRING LOKRING JOINT Figure 23 LOKRING Figure 24 LOKRING TOOL ...
Страница 11: ...CIRCUIT DIAGRAM 10 NOTE 1 This is a basic diagram and specifications vary in different localities ...
Страница 31: ...2 REPLACEMENT PARTS LIST 31 ...
Страница 32: ...3 PWB ASS Y DISPLAY AND PARTS LIST 32 ...
Страница 33: ...5 PWB circuit drawing The PWB circuit drawing may change without notice 33 ...
Страница 34: ... 34 ...
Страница 41: ...P No 3828JS8027F ...