7) TEMPERATURE COMPENSATION
• TEMPERATURE COMPENSATION TABLE by adjusting resistance values. (the temp difference compared to the present
temp.)
eg) If the compensation resistance of freezer compartment is changed from 10K (present resistance) to 18K (revised
resistance), the temp of freezer compartment goes up by +2°C.
- 26 -
FREEZER ROOM
RESISTANCE VALUES(R1)
TEMPERATURE COMPENSATION
REMARKS
180 k
Ω
+ 5.0°C
COMPENSATE WARMLY
56 k
Ω
+4.0°C
33 k
Ω
+3.0°C
18 k
Ω
+2.0°C
12 k
Ω
+1.0°C
10 k
Ω
0°C
STANDARD
8.2 k
Ω
-1.0°C
5.6 k
Ω
-2.0°C
3.3 k
Ω
-3.0°C
2 k
Ω
-4.0°C
470
Ω
-5.0°C
COMPENSATE COOLLY