Fuse Inspection
- Visually inspect for fuse broken.
- When a fuse is destroyed, visually inspect for breaking of IPM and IC209 and additionally check it with a multi-test.
Inverter Parts Inspection
- Visually inspect for breaking of IPM and IC209 and additionally check it with a multi-test (check for short).
Bridge Diode Inspection
- Bridge diode is considered as destroyed if value of10W or less is shown in every case when measuring resistance with a multi-test
for 2 terminals of
4 diode terminals.
※
Power should be turned on again after checking all parts because series of detects may occur when powering on in a simple parts
defect status for parts defect related with an inverter.