Does the cold-air come out of
the top of the main duct?
Yes
No
Check the
Damper
itself
Enter the TEST 1 MODE
Does not cold-air come
out of the top of the main
duct?
No
Yes
After reset the unit, take steps to PCB as
follows for temperature compensation.
1. replacing RCR1
2. Compensate with Jump wire cutting
Checking Damper itself
Is the resistance
Values between (1) & (4),
(2) & (3) like as below?
No
Yes
Test Point
Result
(1) To (4)
369 ~ 451 Ω
(2) To (3)
369 ~ 451 Ω
Replace
Damper
Resistance of Damper
Check the
Damper
itself
(4)YL (2)WH
(1)RD (3)BL
RCR1
Temp.
Compassion
Remark
180
㏀
+ 2.5 deg
Warm
56
㏀
+ 2.0 deg
33
㏀
+ 1.5 deg
18
㏀
+ 1.0 deg
12
㏀
+ 0.5 deg
10
㏀
0 deg
Current
Jump
Wire
Temp.
Compassion
JCR1
+1.0 deg
JCR2
+1.0 deg
Cutting both jumpers affords a
2º compensation
- 50-
Содержание GC-B197HWL
Страница 13: ...2 8 Failure Checking Procedures Heavy Repair Method of Refrigerator by Application of Refrigerant 13 ...
Страница 15: ...PARTS IDENTIFICATION 15 Frame Display Cover PWB o N f e R 2 ...
Страница 30: ... 30 3 PWB Parts Drawings and List 3 1 PWB Assembly Main Parts Drawings EXPLATION FOR MICOM CIRCUIT ...
Страница 31: ... 31 EXPLATION FOR MICOM CIRCUIT ...
Страница 32: ...CIRCUIT 32 ...
Страница 52: ...Attachments Resistance of Sensor Temp F Sensor Resistance R1 R2 D RT Sensor Resistance 52 ...
Страница 94: ...EXPLODED VIEW 210B 210B 210B 210C 210C 202A 205F 201A 203A 207A 207A 501A 207A 279B 207A 279A 200A 94 ...
Страница 95: ...EXPLODED VIEW 230A 233A 231A 234A 212G 147A 243E 241A 241C 241B 240B 240B 240D 240C 232A 205F 95 ...
Страница 99: ......