2
5
-
5) LED blinks five times, then repeats (Locked Piston)
Purpose: To detect locked piston
Cause: Lack of oil to the cylinder, cylinder or piston damaged and or restricted discharge.
A Locked Piston can also be caused by foreign materials inside the compressor.
Logic: Compressor is forced off and tries to restart within 2.5 minutes.
Blink Blink Blink Blink Blink OFF
Protection
logic
Check B
Blink 5 times
(Lock Piston Trip)
Check B3
Compressor
Doesn’t work
Compressor
Doesn’t work
Hi side
restriction
Repeat
Check Procedure
Reset
Power
Sealed
system
Repair
Replace
Compressor
N
Y
N
Y
COMPRESSOR